Rapid isolation of high solute amounts using an online four-dimensional preparative system: normal phase-liquid
Danilo Sciarrone1, Sebastiano Pantò, Peter Quinto Tranchida
1Dipartimento di Scienze del Farmaco e dei Prodotti per la Salute, Università di Messina , Viale Annunziata, 98168 Messina, Italy.
Abstract:
This study reports the recent evolution of a multidimensional GC-GC-GC preparative system, now combined with an online LC preseparation step, operated under normal phase conditions. It is herein shown that the four-dimensional instrument can collect sample components with a concentration lower than 10%, in a short time period, while maintaining a high level of analyte purity. The LC dimension allows (I) the injection of higher sample amounts, compared to "direct" GC injection; (II) a polarity-based preseparation, leading to the GC injection of simplified subsamples, and thus reducing the possibility of coelutions; (III) to eliminate the essential-oil "matrix", replacing it with the LC mobile phase (the GC system is more protected from potential contamination); (IV) the LC mobile phase is of much lower viscosity with respect to a pure, or highly concentrated essential oil, avoiding difficulties in the syringe sample withdrawal process, prior to GC injection. System optimization was performed by using standard solutions; in addition, a very complex sample, namely, vetiver essential oil, was subjected to the preparative process, with the scope of isolating two low-amount constituents (namely, α-amorphene and β-vetivone). The latter two sesquiterpenoids, which accounted for 1.7 and 4.0% of the sample (considering the volatiles), respectively, were successfully collected at the milligram level, in a one-day work period, with a purity degree in excess of 90%.
More Related Videos
10:00Characterization of Proteins by Size-Exclusion Chromatography Coupled to Multi-Angle Light Scattering SEC-MALS
Published on: June 20, 2019
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...