The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Isolated acetabular revision with ceramic-on-ceramic bearings using a ceramic head with a metal sleeve
Yeesuk Kim1, Young-Ho Kim2, Kyu-Tae Hwang1
1Department of Orthopedic Surgery, Hanyang University Hospital, Seoul, South Korea.
Insights
This study found that using ceramic heads with metal sleeves for acetabular revision surgery is a reliable option. It demonstrated significant improvements in hip function and a high survival rate for the acetabular cup.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
Background:
- Acetabular revision surgery is complex, aiming to restore hip function and implant longevity.
- Ceramic-on-ceramic bearings are increasingly used, but their performance in revision settings requires evaluation.
Purpose of the Study:
- To evaluate the outcomes of isolated acetabular revision using ceramic-on-ceramic bearings with a ceramic head and metal sleeve.
Main Methods:
- Retrospective review of 53 hip revision surgeries.
- Analysis of patient demographics, follow-up duration, functional scores, and complication rates.
- Comparison of acetabular bone defects in cases of cup loosening versus stable cups.
Main Results:
- Mean modified Harris hip score improved significantly from 47.5 to 84.7 (P<0.001).
- Acup survival rate was 94.3% at mid-term follow-up.
- Two cases of squeaking and three cases of cup loosening (requiring re-revision) were reported. Significant differences in acetabular bone defects were noted between loose and stable cup groups (P=0.018). No ceramic fractures or osteolysis occurred.
Conclusions:
- Ceramic heads with metal sleeves offer a reliable solution for isolated acetabular revisions.
- This bearing type shows promising mid-term survival rates and functional improvement, despite a small incidence of loosening and squeaking.
Abstract:
The purpose of this study is to evaluate results of isolated acetabular revision with ceramic-on-ceramic bearings using a ceramic head with a metal sleeve. A retrospective review of fifty-three hips was performed. The mean patient age was 49.9years and the mean follow-up period was 5.7years. The mean modified Harris hip score improved from 47.5, pre-operatively, to 84.7 at the time of last follow-up (P<0.001). Two patients reported squeaking of the hip. Three patients experienced loosening cup, necessitating re-revision surgery. There was a significant difference of acetabular bone defect between loose cup group and stable cup group (P=0.018). There were no ceramic fractures and no osteolysis. The survival rate of the acetabular cup at the mid-term follow-up was 94.3%. In conclusion, ceramic head with a metal sleeve can be a reliable option for isolated acetabular revision.