Related Experiment Video
Updated: May 1, 2026

Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
Published on: January 28, 2019
On the use of continuous relative phase: Review of current approaches and outline for a new standard
Peter F Lamb1, Michael Stöckl2
1School of Physical Education, Sport and Exercise Sciences, University of Otago, 56 Union St West, Dunedin 9016, New Zealand; Faculty of Sports and Health Science, Technische Universität München, Georg-Brauchle-Ring 60/62, 80336 Munich, Germany.
Background:
In this paper we review applications of continuous relative phase and commonly reported methods for calculating the phase angle. Signals with known properties as well as empirical data were used to compare methods for calculating the phase angle.
Findings:
Our results suggest that the most valid, robust and intuitive results are obtained from the following steps: 1) centering the amplitude of the original signals around zero, 2) creating analytic signals from the original signals using the Hilbert transform, 3) calculating the phase angle using the analytic signal and 4) calculating the continuous relative phase.
Interpretations:
The resulting continuous relative phase values are free of frequency artifacts, a problem associated with most normalization techniques, and the interpretation remains intuitive. We propose these methods for future research using continuous relative phase in studies and analyses of human movement coordination.
More Related Videos
14:09Quantitative Optical Microscopy: Measurement of Cellular Biophysical Features with a Standard Optical Microscope
Published on: April 7, 2014
05:59Author Spotlight: Unlocking New Insights in fNIRS Studies - A Novel Framework for Inter-Brain Synchrony Analysis
Published on: October 6, 2023
Related Concept Videos
The Phase Rule
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Continuous -time Fourier Transform
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Phase Changes
A substance melts or freezes at a temperature called its melting point and boils or condenses at its boiling point. These temperatures depend on pressure. High pressure favors the denser form of the substance, so typically, high pressure...