Related Experiment Videos

The interrupted power law and the size of shadow banking

Davide Fiaschi1, Imre Kondor2, Matteo Marsili3

  • 1Dipartimento di Economia e Management, University of Pisa, Pisa, Italy.

Plos One
|April 15, 2014
PubMed

Related Concept Videos

Limit Laws II01:26

Limit Laws II

In calculus, limit laws serve as foundational tools for evaluating the behavior of functions as inputs approach specific values. Among these, the laws concerning quotients, powers, and roots are particularly useful in breaking down complex expressions.The Quotient Law allows the limit of a division between two functions to be calculated by dividing their individual limits, provided the limit of the denominator exists and is not zero. For example,The Power Law states that the limit of a function...
372
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
742
Lossy Lines and Overvoltages01:22

Lossy Lines and Overvoltages

Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
423
Instantaneous Power01:22

Instantaneous Power

Instantaneous power is important in electrical circuits, mainly when dealing with sinusoidal input. Instantaneous power, denoted as p(t), results from the multiplication of the instantaneous voltage (v(t)) across an element and the instantaneous current (i(t)) flowing through it. This relationship adheres to the passive sign convention and represents a fundamental principle in electrical engineering.
1.1K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
777
The Swing Equation01:21

The Swing Equation

The Swing Equation is a fundamental tool in power system dynamics, especially for analyzing the behavior of generating units like three-phase synchronous generators. This equation emerges from applying Newton's second law to the rotor of a generator, encompassing factors such as inertia, angular acceleration, and the interplay between mechanical and electrical torques.
In a steady-state operation, the mechanical torque (Τm) supplied to the generator is balanced by the electrical torque...
1.6K