Thermocapillary flow in glass tubes coated with photoresponsive layers

J Rodrigo Vélez-Cordero1, A M Velázquez-Benítez, J Hernández-Cordero

  • 1Instituto de Investigaciones en Materiales, Universidad Nacional Autónoma de México , Apdo. Postal 70-360, México D.F. 04510, México.

Related Concept Videos

Steady, Laminar Flow in Circular Tubes01:23

Steady, Laminar Flow in Circular Tubes

Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely...
2.0K
Rise of Liquid in a Capillary Tube01:18

Rise of Liquid in a Capillary Tube

When very thin cylindrical tubes, called capillaries, are dipped in a liquid, the liquid rises or falls in the tube compared to the surrounding liquid. This phenomenon is called capillary action. Capillary action occurs due to the combination of two opposing forces: the cohesive forces of the liquid, which cause it to stick to itself and form a rounded shape, and the adhesive forces between the liquid and the walls of the container, which cause the liquid to be attracted to the container walls.
3.1K
Thermosensation01:43

Thermosensation

Peripheral thermosensation is the perception of external temperature. A change in temperature (on the surface of the skin and other tissues) is detected by a family of temperature-sensitive ion channels called Transient Receptor Potential, or TRP, receptors. These receptors are located on free nerve endings. Those detecting cold temperatures are closer to the surface of the skin than the nerve endings detecting warmth. These thermoTRP channels, while temperature selective, have relatively...
29.7K
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
11.0K