Related Experiment Video
Updated: May 1, 2026

Author Spotlight: Advancements in DNA Nanosensors – Addressing Sensitivity and Selectivity Challenges in Molecular Detection
Published on: February 9, 2024
Amplified and selective detection of Ag+ ions based on electrically contacted enzymes on duplex-like DNA scaffolds
Gang Xu1, Guangfeng Wang1, Yanhong Zhu1
1Key Laboratory of Chem-Biosensing, Anhui province; Key Laboratory of Functional Molecular Solids, Anhui province; College of Chemistry and Materials Science, Center for Nano Science and Technology, Anhui Normal University, Wuhu 241000, PR China; State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082, PR China.
Abstract:
In the present study, ultrasensitive detection of Ag(+) is demonstrated by a biocatalytic signal amplification system which is realized by only one DNA sequence based electrical contacted enzyme structure and the Au nanoparticles/Carbon nanodots (AuNPs/C-dots) composite immobilization platform. In the presence of Ag(+), with the interaction of cytosine-Ag(+)-cytosine (C-Ag(+)-C), cytosine-rich DNA sequence labeled with methylene blue (MB) molecules near 5' end and Glucose Oxidase (GOx) at 3' end, has a self-hybridization and then forms a duplex-like structure which makes MB and GOx approach the AuNPs/C-dots modified electrode. MB units can then act as a relay that electrically contacts GOx with the AuNPs/C-dots modified electrode and activate the bioelectrocatalyzed oxidation of glucose to glucose acid. In consequence, based on the bioelectrocatalyzed signal amplification on the AuNPs/C-dots platform, Ag(+) could be quantitatively detected in the range of 10(-11)-10(-5) M with a low detection limit of 3 pM. Also, there is an excellent selectivity against other interferential metal ions. The detection of Ag(+) ions was realized by Ag(+) self-induced conformational change of DNA scaffold which involved only one oligonucleotide showing its convenience and availability.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Southern Blot
Denatured DNA fragments must be transferred onto a carrier membrane from the gel to make it accessible to a probe - a small ssDNA fragment complementary to the target DNA...

