Related Experiment Video
Updated: May 1, 2026

A Novel Rescue Technique for Difficult Intubation and Difficult Ventilation
Published on: January 17, 2011
Making endotracheal intubation easy and successful, particularly in unexpected difficult airway
Susanne Abdulla1, Sina Abdulla2, Karl-Peter Schwemm3
1Department of Anesthesiology and Intensive Care Medicine, Klinikum Bernburg, Martin Luther-University Halle-Wittenberg, Bernburg, Germany ; Department of Neurology, Otto-von-Guericke University, Magdeburg, Germany ; Department of Neurology, Medizinische Hochschule Hannover, Hannover, Germany.
Background:
Difficult intubation, most often due to poor view of the vocal cords on laryngoscopy is an intermittent and often challenging problem for clinically practicing anesthesiologists, maxillofacial surgeons, ear nose, and throat (ENT), emergency, and critical care physicians.
Purpose:
We present a new approach for facilitating difficult intubation and evaluate its efficacy in a retrospective observational study.
Settings And Design:
Operating room, emergency department, intensive care unit (ICU), retrospective observational study.
Materials And Methods:
A semirigid 5.6 Rüsch tracheal tube introducer (bougie) with its soft tip protruding at least 6 cm (=4 digits) beyond the distal end of the tube was used. After its insertion through the larynx under laryngoscopy, the tube was gently advanced upon rotation at 360° clockwise.
Statistical Analysis:
Descriptive.
Results:
Anesthesia services were analyzed on 10,363 patients over 12 months. In 2453 patients (23.7%) (Group A) intubated in the usual way, difficulties were encountered in 63 patients (2.6%). They were managed either with tube rotation technique (n = 60) or Bonfils endoscope (n = 3). In contrast, 2807 patients (27.1%) (Group B) were intubated using tube rotation technique with introducer. Difficult intubations occurred only in three patients (0.11%) who could be managed with tube rotation by experienced consultant anesthesiologists.
Conclusions:
The tube rotation technique for intubation was introduced during the Gulf War and has been practiced for the past 19 years without any obvious damage to the trachea in Germany. However, it should be used only by physicians being well familiar with this technique. In addition, well designed controlled studies are needed.
More Related Videos
04:43Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
04:30Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation II: ACLS Airway Management
Tracheostomy Care I: Pre-procedural Steps
Required Equipment