Separation performance of cucurbit[8]uril and its coordination complex with cadmium (II) in capillary gas
Tao Sun1, Ningning Ji2, Meiling Qi1
1Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials and School of Chemistry, Beijing Institute of Technology, Beijing 100081, China.
Abstract:
Here we report the investigation of using cucurbit[8]uril (CB8) and its coordination complex with cadmium (II) (CB8-Cd) as stationary phases for capillary gas chromatography (GC). The prepared capillary columns of CB8 and CB8-Cd stationary phases achieved column efficiency of 2200plates/m and 1508plates/m, respectively, and showed weak polarity based on the measured McReynolds constants. Their separation performance was investigated by GC separation of mixtures of different types while a commercial column was used for comparison. The CB8 stationary phase achieved high resolution for a wide range of analytes from nonpolar to polar while the CB8-Cd stationary phase exhibited good separation mainly for nonpolar to weak polar analytes. The CB stationary phases differ from the commercial one in terms of retention behaviors and resolving ability due to their different molecular interactions with analytes. Moreover, energy effect on the retention of analytes on CB8 and CB8-Cd stationary phases was examined, showing that retention on CB8 column was determined mainly by enthalpy change for polar analytes and by both enthalpy change and entropy change for weak polar analytes whereas retention on CB8-Cd column was mainly controlled by entropy change. This work demonstrates the great potential of CB8 and CB8-Cd stationary phases as a new type of GC stationary phases in GC analysis.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion-Exchange Chromatography
![Quantitative SERS Detection of Uric Acid via Formation of Precise Plasmonic Nanojunctions within Aggregates of Gold Nanoparticles and Cucurbit[n]uril](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F61682.jpg&w=3840&q=50)

