Related Experiment Video
Updated: Apr 30, 2026

Chemiluminescence-based Assays for Detection of Nitric Oxide and its Derivatives from Autoxidation and Nitrosated Compounds
Published on: February 16, 2022
A reversible dual mode chemodosimeter for the detection of cyanide ions in natural sources
Balaraman H Shankar1, Dhanya T Jayaram, Danaboyina Ramaiah
1Photosciences and Photonics Section, Chemical Sciences and Technology Division, CSIR-National Institute for Interdisciplinary Science and Technology (CSIR-NIIST), Trivandrum-695019, Kerala (India), Fax: (+91) 471-2490186 or 2491712.
Abstract:
Herein, we report the synthesis of two indolium probes 1 and 2 based on anthracene and pyrene derivatives and their interactions with various anions. Of these probes, the pyrene conjugate 2 acts as a dual colorimetric and fluorescent chemodosimeter for the selective and sensitive detection of cyanide ions. The detection limit of probe 2 for CN(-) ions was found to be 10 ppb (30 nM). The nature of interaction has been thoroughly studied through various techniques such as (1)H NMR and IR spectroscopy, HRMS, and isothermal calorimetric (ITC) studies. These studies confirm that probe 2 forms a 1,2-adduct in the presence of CN(-) ions. Kinetic studies using probe 2 showed the completion of the reaction within 15 s with a rate constant of k' = 0.522±0.063 s(-1). This probe can be coated on a solid surface (dipstick) and a polymer matrix for the on-site analysis and quantification of endogenous cyanide ions in natural sources such as Indian almonds.
More Related Videos
08:25Measuring Nitrite and Nitrate, Metabolites in the Nitric Oxide Pathway, in Biological Materials using the Chemiluminescence Method
Published on: December 25, 2016
09:51TD-DFT Guided Advanced E-Eye Sensing Technique for On-site Quantification of Fe, Cr, F, and As in the Environmental, Biological, and Food Samples
Published on: September 19, 2025
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Controlled-Current Coulometry: Overview
High-Performance Liquid Chromatography: Types of Detectors
Voltammetric Techniques: Cyclic Voltammetry
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Redox Titration: Overview