Related Experiment Video
Updated: Apr 30, 2026

Synthesis and Mass Spectrometry Analysis of Oligo-peptoids
Published on: February 21, 2018
Electrospray ionization tandem mass spectrometry study of six isomeric cationic amphiphiles with ester/amide linker
D Vijay Darshan1, B G N Chandar, M Srujan
1National Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical Technology, Hyderabad, 500007, India.
Rationale:
Isomeric cationic amphiphiles differing only in the orientation of the linker group have been demonstrated to possess dramatically changed gene transfer efficacies. Studies aimed at understanding structure-stability correlations of such isomeric cationic amphiphiles at the molecular level are yet to be undertaken. Such studies may throw significant new insights into the mechanistic origin on their contrasting bioactivities.
Methods:
Electrospray ionization mass spectrometry (ESI-MS) and multi-stage tandem mass spectrometric (MS(n)) experiments were performed on a LCQ ion trap mass spectrometer. The decomposition pathway was confirmed by high-resolution mass spectrometry data from a quadrupole time-of-flight (Q-TOF) mass spectrometer. Dissociation curves were drawn based on the intensities of precursor and product ions.
Results:
The collision-induced dissociation (CID) spectra of the M(+) ion of each isomeric pair showed distinct product ions (3 pairs). Normal esters (1 and 3) showed abundant product ions with a neighboring group participation (NGP) reaction and reverse esters (lipid 2 and 4) showed McLafferty rearrangement product ions. The spectra of a normal amide (5) and a reverse amide (6) are similar to that found in the corresponding ester, except for the absence of the McLafferty rearrangement in 6. Dissociation curves revealed that normal esters/amide decompose at lower energy than those of corresponding reverse esters/amide.
Conclusions:
The lipids which easily decompose (flexible) show dramatically enhanced gene delivery capabilities and the lipids which decompose at higher collision energy (CE) values (rigid) are transfection incompetent.
More Related Videos
12:59A Study of the Complexation of MercuryII with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
11:04Ion Mobility-Mass Spectrometry Techniques for Determining the Structure and Mechanisms of Metal Ion Recognition and Redox Activity of Metal Binding Oligopeptides
Published on: September 7, 2019
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example,...
Tandem Mass Spectrometry
Mass Spectrometry of Amines
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Chemical Ionization (CI) Mass Spectrometry