Related Experiment Video
Updated: Aug 19, 2026

Use of a Monocyte Monolayer Assay to Evaluate Fcγ Receptor-mediated Phagocytosis
Published on: January 2, 2017
A redetermination of the concentration of alpha 2-macroglobulin in human plasma
1Cutter Laboratories Inc., Berkeley, California.
Abstract:
The concentration of alpha 2-macroglobulin in human plasma has been remeasured utilizing a carefully isolated and characterized sample of alpha 2-macroglobulin as a standard. A highly purified sample of alpha 2-macroglobulin with a total trypsin binding capacity of 1.7 mol trypsin/mol alpha 2-macroglobulin was used as a standard for both a radial immunodiffusion and a rocket immunoelectrophoresis technique. With this preparation as a standard, the concentration of alpha 2-macroglobulin in a normal plasma pool over 10,000 donors was found to be about 1.2 mg/ml. A similar concentration (1.3 mg/ml) was found when using a functional trypsin binding assay. This concentration is considerably less than the usually accepted mean of the normal range for alpha 2-macroglobulin.