Inter-rater reliability and measurement error of sonographic muscle architecture assessments
Niklas König1, Michael Cassel, Konstantina Intziegianni
1University Outpatient Clinic, Sports Medicine and Sports Orthopedics, University of Potsdam, Am Neuen Palais 10, Haus 12, 14469 Potsdam, Germany. mcassel@uni-potsdam.de.
Objectives:
Sonography of muscle architecture provides physicians and researchers with information about muscle function and muscle-related disorders. Inter-rater reliability is a crucial parameter in daily clinical routines. The aim of this study was to assess the inter-rater reliability of sonographic muscle architecture assessments and quantification of errors that arise from inconsistent probe positioning and image interpretation.
Methods:
The medial gastrocnemius muscle of 15 healthy participants was measured with sagittal B-mode ultrasound scans. The muscle thickness, fascicle length, superior pennation angle, and inferior pennation angle were assessed. The participants were examined by 2 investigators. A custom-made foam cast was used for standardized positioning of the probe. To analyze inter-rater reliability, the examinations of both raters were compared. The impact of probe positioning was assessed by comparison of foam cast and freehand scans. Error arising from picture interpretation was assessed by comparing the investigators' analyses of foam cast scans independently. Reliability was expressed as the intraclass correlation coefficient (ICC), inter-rater variability (IRV), Bland-Altman analysis (bias ± limits of agreement [LoA]), and standard error of measurement (SEM).
Results:
Inter-rater reliability was good overall (ICC, 0.77-0.90; IRV, 9.0%-13.4%; bias ± LoA, 0.2 ± 0.2-1.7 ± 3.0). Superior and inferior pennation angles showed high systematic bias and LoA in all setups, ranging from 2.0° ± 2.2° to 3.4° ± 4.1°. The highest IRV was found for muscle thickness (13.4%). When the probe position was standardized, the SEM for muscle thickness decreased from 0.1 to 0.05 cm.
Conclusions:
Sonographic examination of muscle architecture of the medial gastrocnemius has good to high reliability. In contrast to pennation angle measurements, length measurements can be improved by standardization of the probe position.
More Related Videos
08:48Author Spotlight: Exploring the Complexities of Achilles Tendon Injuries — Research and Future Directions
Published on: October 27, 2023
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):