Room temperature fabrication of post-modified zeolitic imidazolate framework-90 as stationary phase for open-tubular
Li-Qing Yu1, Cheng-Xiong Yang1, Xiu-Ping Yan1
1State Key Laboratory of Medicinal Chemical Biology (Nankai University), Collaborative Innovation Center of Chemical Science and Engineering (Tianjin), and Research Center for Analytical Sciences, College of Chemistry, Nankai University, 94 Weijin Road, Tianjin 300071, China.
Abstract:
Metal-organic frameworks (MOFs) are attractive as porous stationary phase for open-tubular capillary electrochromatography (OT-CEC) due to their fascinating structures and unusual properties. Here we report a directly covalent bonding approach to prepare uniform and dense MOF film on the inner wall of fused silica capillary at room temperature for OT-CEC. Zeolitic imidazolate framework-90 (ZIF-90) as a model MOF because it not only possesses large surface area and high stability but also provides the free aldehyde groups to bond to the inner surface of capillary via covalent bond. X-ray diffraction, scan electron microscopy, and UV-vis spectrophotometry were used to confirm the bonding of the ZIF-90 to the inner wall of the silica capillary. The ZIF-90 coating not only increased the phase ratio of open-tubular column, but also improved the interactions of tested analytes and the coating. Owing to the porous structure of ZIF-90 and hydrophobic interactions between the analytes and the organic ligands of ZIF-90, three groups of isomers, neutral and basic compounds and nonsteroidal anti-inflammatory drugs were well separated on the ZIF-90 bonded column. The precisions (relative standard deviation, RSD) of retention time, half peak width and peak area for three consecutive runs were 0.3-1.2%, 1.3-6.0% and 1.5-5.2%, respectively. The run-to-run, day-to-day, and column-to-column precisions (RSDs) for the electroosmotic flow of the ZIF-90 bonded column were 0.2%, 0.4%, and 1.9%, respectively. Moreover, the ZIF-90 bonded column could stand more than 230 runs without observable change in the separation efficiency.
More Related Videos
07:45Electrophoretic Crystallization of Ultrathin High-performance Metal-organic Framework Membranes
Published on: August 16, 2018
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Ion Exchange