Thermal Measurement Techniques in Analytical Microfluidic Devices
Published on: June 3, 2015
Measuring the actual timing of liquid-reward delivery using a thermistor
Koji Toda1, Shigeru Yamane2, Shinya Yamamoto2
1Systems Neuroscience, Human Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba 305-8568, Japan; Department of Neurobiology, Duke University School of Medicine, Durham, NC 27701, USA; Japan Society for the Promotion of Science, Tokyo 102-0083, Japan.
Background:
Determining the exact timing of reward delivery is critical in neurophysiological experiments. Despite the importance of this parameter, techniques for precisely measuring the exact delivery time of a liquid reward have been underdeveloped. Although there is always some latency between the computer command and reward delivery, the former has been used routinely to mark reward onset time.
New Method:
To address this issue, we developed two methods of estimating the time of liquid reward delivery. First, electrical conduction between two contacts at the outlet of a pipe was detected. This technique was impractical during normal experiments but was a direct and reliable method of measuring the precise timing of water outflow. Second, a self-heating thermistor inside the fluid delivery pipe was used. The thermistor detected a decrease in temperature upon commencement of water flow.
Results:
The electrical contact began 50-80ms after the computer command. The thermistor-based delivery timing estimation was ∼40ms later than that measured by the electrical contact. The time lag was constant with minimal variance between trials within the same experimental setup.
Comparison With Existing Method:
As far as the time difference between the two methods is measured, the timing of water outflow can be estimated using the thermistor-based device. This is the first method of estimating the onset time of water flow during experiments.
Conclusions:
Our new system could be used to quantify setup-dependent changes in the timing of reward delivery, improving the sophistication of reward assessments in neurophysiological experiments.
Related Concept Videos
Measuring Reaction Rates
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Thermosensation
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...