Related Experiment Video
Updated: Apr 30, 2026

Continuously-stirred Anaerobic Digester to Convert Organic Wastes into Biogas: System Setup and Basic Operation
Published on: July 13, 2012
Simultaneous organic carbon and nitrogen removal in an anoxic-oxic activated sludge system under various operating
Kashif Rasool1, Dae Hee Ahn2, Dae Sung Lee1
1Department of Environmental Engineering, Kyungpook National University, 80 Daehak-ro, Buk-gu, Daegu 702-701, Republic of Korea.
Abstract:
This study investigated a bench-scale anoxic-oxic activated sludge system for integrated removal of COD and nitrogen. The experimental unit includes four chambers and continuous feeding in first chamber without recycle of nitrified liquid from aerobic to anoxic chamber unlike the conventional anoxic-oxic process. Recycled excessive sludge was used for the purpose of recycling nitrified mixed liquor. Synthetic wastewater with average loading rates of 0.53 kg COD/m(3)/d and 0.067 kg NH4(+)-N/m(3)/d was fed to the reactor system at hydraulic residence times (HRT) of 24 and 18 h. The results of 100 days operation showed high removal efficiencies of organic matter of about 97% as total COD and more than 99% removal of ammonia-nitrogen. In anoxic-oxic operation phase, total inorganic nitrogen (TIN) removal was about 66% by pre-denitrification. Moreover, the solid liquid separation through final clarifier was excellent without any suspended solid in the effluent.
More Related Videos
Related Concept Videos
Bioreactor Design and Operational System
Bioreactor Controls-II
Bioremediation