Validation of self-reported maternal and infant health indicators in the Pregnancy Risk Assessment Monitoring System

Patricia Dietz1, Jennifer Bombard, Candace Mulready-Ward

  • 1Division of Reproductive Health, Centers for Disease Control and Prevention, Atlanta, GA, USA, PDietz@cdc.gov.

To assess the validity of self-reported maternal and infant health indicators reported by mothers an average of 4 months after delivery. Three validity measures-sensitivity, specificity and positive predictive value (PPV)-were calculated for pregnancy history, pregnancy complications, health care utilization, and infant health indicators self-reported on the Pregnancy Risk Assessment Monitoring System (PRAMS) questionnaire by a representative sample of mothers delivering live births in New York City (NYC) (n = 603) and Vermont (n = 664) in 2009. Data abstracted from hospital records served as gold standards. All data were weighted to be representative of women delivering live births in NYC or Vermont during the study period. Most PRAMS indicators had >90 % specificity. Indicators with >90 % sensitivity and PPV for both sites included prior live birth, any diabetes, and Medicaid insurance at delivery, and for Vermont only, infant admission to the NICU and breastfeeding in the hospital. Indicators with poor sensitivity and PPV (<70 %) for both sites (i.e., NYC and Vermont) included placenta previa and/or placental abruption, urinary tract infection or kidney infection, and for NYC only, preterm labor, prior low-birth-weight birth, and prior preterm birth. For Vermont only, receipt of an HIV test during pregnancy had poor sensitivity and PPV. Mothers accurately reported information on prior live births and Medicaid insurance at delivery; however, mothers' recall of certain pregnancy complications and pregnancy history was poor. These findings could be used to prioritize data collection of indicators with high validity.

Related Concept Videos

Assessment of apical radial pulse01:25

Assessment of apical radial pulse

Apical-Radial (A-R) Pulse Assessment
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
1.6K
Pharmacovigilance01:19

Pharmacovigilance

Post-marketing surveillance is a critical component of pharmaceutical regulation, often uncovering unanticipated adverse drug reactions (ADRs) once a drug is widely used over an extended period.
This process, termed pharmacovigilance, aims to detect, evaluate, and minimize harmful effects related to medication use. The data collection for pharmacovigilance depends on spontaneous reporting systems, where healthcare professionals or patients voluntarily report suspected ADRs.
In some cases, there...
2.0K
Methods of Documentation II: POMR01:26

Methods of Documentation II: POMR

The Problem-Oriented Medical Record (POMR) revolutionized medical record-keeping by introducing a systematic approach focusing on the patient's problems rather than merely listing symptoms. Dr. Lawrence Weed's introduction of this method in the 1960s marked a significant advancement in medical documentation. The POMR framework consists of four key components: the database, problem list, plan of care, and progress notes.
1.4K
Regression Toward the Mean01:52

Regression Toward the Mean

Regression toward the mean (“RTM”) is a phenomenon in which extremely high or low values—for example, and individual’s blood pressure at a particular moment—appear closer to a group’s average upon remeasuring. Although this statistical peculiarity is the result of random error and chance, it has been problematic across various medical, scientific, financial and psychological applications. In particular, RTM, if not taken into account, can interfere when...
6.3K
Guidelines For Measuring Vital Signs01:19

Guidelines For Measuring Vital Signs

Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
3.5K
Data Validation01:03

Data Validation

Data validation is an essential part of a comprehensive assessment. Validation is confirming or verifying and opening the door to gathering more assessment data as it clarifies vague or unclear data. The process of checking and verifying the collected information is called data validation. The primary purpose of data validation is to ensure data is as free from error, bias, and misinterpretation as possible.
Nursing assessment guides are generally based on holistic models rather than medical...
6.4K