The unfolded protein response governs integrity of the haematopoietic stem-cell pool during stress

Peter van Galen1, Antonija Kreso1, Nathan Mbong1

  • 11] Princess Margaret Cancer Centre, University Health Network, Toronto, Ontario M5G 2M9, Canada [2] Department of Molecular Genetics, University of Toronto, Toronto, Ontario M5S 1A8, Canada.

Nature
|April 30, 2014
PubMed

The blood system is sustained by a pool of haematopoietic stem cells (HSCs) that are long-lived due to their capacity for self-renewal. A consequence of longevity is exposure to stress stimuli including reactive oxygen species (ROS), nutrient fluctuation and DNA damage. Damage that occurs within stressed HSCs must be tightly controlled to prevent either loss of function or the clonal persistence of oncogenic mutations that increase the risk of leukaemogenesis. Despite the importance of maintaining cell integrity throughout life, how the HSC pool achieves this and how individual HSCs respond to stress remain poorly understood. Many sources of stress cause misfolded protein accumulation in the endoplasmic reticulum (ER), and subsequent activation of the unfolded protein response (UPR) enables the cell to either resolve stress or initiate apoptosis. Here we show that human HSCs are predisposed to apoptosis through strong activation of the PERK branch of the UPR after ER stress, whereas closely related progenitors exhibit an adaptive response leading to their survival. Enhanced ER protein folding by overexpression of the co-chaperone ERDJ4 (also called DNAJB9) increases HSC repopulation capacity in xenograft assays, linking the UPR to HSC function. Because the UPR is a focal point where different sources of stress converge, our study provides a framework for understanding how stress signalling is coordinated within tissue hierarchies and integrated with stemness. Broadly, these findings reveal that the HSC pool maintains clonal integrity by clearance of individual HSCs after stress to prevent propagation of damaged stem cells.

Related Concept Videos

Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy11:27

Preparation and Respirometric Assessment of Mitochondria Isolated from Skeletal Muscle Tissue Obtained by Percutaneous Needle Biopsy

Methods for biopsy of Vastus lateralis, preparation of purified mitochondria, and respirometric profiling are described. The use of small muscle volume makes this technique suitable for clinical research...
20.2K
In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses09:31

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses

Optical coherence tomography (OCT) is a high resolution imaging technique that allows analysis of tissue specific optical properties providing the means for tissue differentiation. We developed needle based OCT, providing real-time imaging combined with on-the-spot tumor differentiation. This publication describes a method for percutaneous, needle based OCT of renal...
9.3K
Three-Dimensional Printing Guide Template Assisted Percutaneous Vertebroplasty (PVP)05:39

Three-Dimensional Printing Guide Template Assisted Percutaneous Vertebroplasty (PVP)

Herein, we present a three-dimensional printing guide template for percutaneous vertebraplasty. A patient with a T11 vertebral compression fracture was selected as a case...
8.2K
A Two-Step Method for Percutaneous Transhepatic Choledochoscopic Lithotomy03:56

A Two-Step Method for Percutaneous Transhepatic Choledochoscopic Lithotomy

This "two-step method" significantly improved the success rate of percutaneous transhepatic choledochoscopy and achieved a better prognosis of intrahepatic and extrahepatic...
2.9K
Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels08:12

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels

This protocol demonstrates in detail how to perform fully endoscopic mitral valve surgery (EMS) with percutaneous cannulation of the groin vessels, using a percutaneous plug-based vascular closure device. Fundamental steps and useful instructions are described in detail for each step.
2.4K
Wet Beveling of Microinjection Needles Utilizing Constant Air Pressure for Feedback on Needle Opening06:00

Wet Beveling of Microinjection Needles Utilizing Constant Air Pressure for Feedback on Needle Opening

This protocol describes the assembly of a pneumatic system for the delivery of pressurized air to a needle during the process of needle beveling. The protocol further describes the beveling process for creating sharp microinjection needles and how to gauge the relative opening size of the...
858