Related Experiment Video
Updated: Apr 30, 2026

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Critical evaluation of spectroscopic indices for organic matter source tracing via end member mixing analysis based
1Department of Environment & Energy, Sejong University, Seoul 143-747, South Korea.
Abstract:
Despite the wide use of absorption and fluorescence spectroscopy for tracking the sources of dissolved organic matter (DOM), there are limited studies on evaluating their source discrimination capabilities at variable solution chemistry (pH, NaCl, Ca(2+), and DOM concentration). For this study, we compared the applicability of several well-known spectroscopic indices via end member mixing analysis based on two contrasting DOM sources (Suwannee River fulvic acid and an algal DOM). The absorption coefficients and the intensities of fluorescent components from parallel factor analysis (PARAFAC) showed linear relationships with increasing algal carbon fraction in the mixture of the two DOMs. In contrast, although they still behaved conservatively, spectral ratio indices such as spectral slopes, ratios of PARAFAC components, humification index, and fluorescence index changed in nonlinear patterns with the mixing ratios. The indices based on PARAFAC results exhibited strong discrimination capabilities, as indicated by high susceptibility to the changes in DOM sources relative to the analytical precision. While variable NaCl concentrations had limited effects, most fluorescence indices were considerably affected by other solution chemistry such as pH, Ca(2+), and DOM level. Our study demonstrated that the applicability of the source discrimination indices should be critically examined especially in the environments with notable changes in the solution chemistry. The solution chemistry effects could be minimized by adjusting samples to a constant condition prior to the measurements or otherwise the effects should be fully taken into account in interpreting the field observations.
Related Concept Videos
Mass Spectrometry: Isotope Effect
Mass Spectrum: Interpretation
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
IR Spectroscopy: Molecular Vibration Overview
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...

