Predicting tenderness of fresh ovine semimembranosus using Raman spectroscopy
Stephanie M Fowler1, Heinar Schmidt2, Remy van de Ven3
1School of Animal and Veterinary Sciences, Charles Sturt University, Wagga Wagga, Australia; Graham Centre for Agricultural Innovation, NSW Department of Primary Industries and Charles Sturt University, Wagga Wagga, Australia.
Abstract:
A hand held Raman probe was used to predict shear force (SF) of fresh lamb m. semimembranosus (topside). Eighty muscles were measured at 1 day PM and after a further 4 days ageing (5 days PM). At 1 day PM sarcomere length (SL) and particle size (PS) were measured and at 5 days PM, SF, PS, cooking loss (CL) and pH were also measured. SF values were regressed against Raman spectra using partial least squares regression and against traditional predictors (e.g. SL) using linear regression. The best prediction of SF used spectra at 1 day PM which gave a root mean square error of prediction (RMSEP) of 11.5 N (Null = 13.2) and the squared correlation between observed and cross validated predicted values (R(2)cv) was 0.27. Prediction of SF based on the traditional predictors had smaller R(2) values than using Raman spectra justifying further study on Raman spectroscopy.
More Related Videos
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
UV–Vis Spectroscopy: Beer–Lambert Law
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...