Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological
Hein Heidbuchel1, Fred H M Wittkampf2, Eliseo Vano3
1Department of Cardiovascular Medicine, University Hospital Gasthuisberg, University of Leuven, 3000 Leuven, Belgium Hein.Heidbuchel@uz.kuleuven.ac.be.
Abstract:
Despite the advent of non-fluoroscopic technology, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies over ablation interventions to device implantation. Moreover, many patients receive additional X-ray imaging, such as cardiac computed tomography and others. More and more complex procedures have the risk to increase the radiation exposure, both for the patients and the operators. The professional lifetime attributable excess cancer risk may be around 1 in 100 for the operators, the same as for a patient undergoing repetitive complex procedures. Moreover, recent reports have also hinted at an excess risk of brain tumours among interventional cardiologists. Apart from evaluating the need for and justifying the use of radiation to assist their procedures, physicians have to continuously explore ways to reduce the radiation exposure. After an introduction on how to quantify the radiation exposure and defining its current magnitude in electrophysiology compared with the other sources of radiation, this position paper wants to offer some very practical advice on how to reduce exposure to patients and staff. The text describes how customization of the X-ray system, workflow adaptations, and shielding measures can be implemented in the cath lab. The potential and the pitfalls of different non-fluoroscopic guiding technologies are discussed. Finally, we suggest further improvements that can be implemented by both the physicians and the industry in the future. We are confident that these suggestions are able to reduce patient and operator exposure by more than an order of magnitude, and therefore think that these recommendations are worth reading and implementing by any electrophysiological operator in the field.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT