Related Experiment Video
Updated: Aug 18, 2026

Bladder Smooth Muscle Strip Contractility as a Method to Evaluate Lower Urinary Tract Pharmacology
Published on: August 18, 2014
Stop-flow measurement of detrusor contractility in bladder outflow obstruction
1Department of Urology, Karolinska Hospital, Stockholm, Sweden.
Abstract:
Detrusor contractility was evaluated by measuring the increase in isometric pressure during a stop test in 25 men with benign prostatic hyperplasia. Before transurethral prostatic resection (TUR), a low pressure increase (delta P det iso) was associated with a large volume of residual urine. After TUR both the speed and the amplitude of isometric detrusor contractions during the stop test increased. A pre-operative low detrusor pressure increase was correlated with a great improvement in flow rate after TUR. The value of the stop-flow test was limited, however, since improvement in other urodynamic parameters could not be predicted.
Related Concept Videos
The Micturition Reflex
The process begins with bladder filling, where the bladder wall stretches as urine accumulates. This stretching activates the urine storage reflex, mediated by the sacral spinal segments and the pontine storage center. Efferent sympathetic impulses stimulate the detrusor muscle to relax and the internal urethral sphincter to contract, facilitating urine...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Urodynamic Studies: Uroflowmetry