Related Experiment Video
Updated: Apr 30, 2026

Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Usefulness of the Shock Index as a secondary triage tool
James Vassallo1, S Horne2, S Ball3
1Underwater Medicine Division, Institute of Naval Medicine, Alverstoke, UK.
Introduction:
Secondary triage at a major incident allows for a more detailed assessment of the patient. In the UK, the Triage Sort (TSO) is the preferred method, combining GCS, systolic BP (SBP) and RR to categorise Priority 1 casualties. The Shock Index (SI) is calculated by dividing HR by SBP (HR/SBP). This study examines whether SI is better at predicting need for life-saving intervention (LSI) following trauma than TSO.
Methods:
A prospective observational study was undertaken. Physiological data and interventions performed in the Emergency Department and operating theatre were prospectively collected for 482 consecutive adult trauma patients presenting to Camp Bastion, Afghanistan, over a 6-month period. A patient was deemed to have required LSI if they received any intervention from a set described previously.
Results:
Complete data were available for 345 patients (71.6%). Of these, 203 (58.8%) were gold standard P1, and 142 (41.2%) were non-P1. The TSO predicted need for LSI with a sensitivity of 58.6% (95% CI 51.8% to 65.4%) and specificity of 88.7% (95% CI 83.5% to 93.9%). Using an SI cut-off >0.75 provided greater sensitivity of 70.0% (95% CI 63.6% to 76.3%) while maintaining an acceptably high (although lower than TSO) specificity of 74.7% (95% CI 67.5% to 81.8%). At this SI cut-off, there was evidence of a difference between TSO and SI in terms of the way in which patients were triaged (p<0.0001).
Discussion:
Our study showed that a SI >0.75 more accurately predicted the need for LSI, while maintaining acceptable specificity. SI may be more useful than TSO for secondary triage in a mass-casualty situation; this relationship in civilian trauma should be examined to clarify whether these results can be more widely translated into civilian practice.
Project Registration Number:
RCDM/Res/Audit/1036/12/0050.
More Related Videos
08:45Echocardiographic Assessment Using Subxiphoid-Only Examination for Hypotensive Patients
Published on: April 18, 2025
10:38Observational Study Protocol for Repeated Clinical Examination and Critical Care Ultrasonography Within the Simple Intensive Care Studies
Published on: January 16, 2019
Related Concept Videos
Therapeutic Index
Cardiopulmonary Resuscitation III: AED Use
Acute Coronary Syndrome III: Diagnostic Studies
Cardiopulmonary Resuscitation IV: Pharmacological Management
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...