Related Experiment Video
Updated: Apr 30, 2026

Improving IV Insulin Administration in a Community Hospital
Published on: June 11, 2012
Insulin pump-associated adverse events in children and adolescents--a prospective study
Benjamin J Wheeler1, Kristine Heels, Kim C Donaghue
11 The Institute of Endocrinology and Diabetes, The Children's Hospital at Westmead , Sydney, Australia .
Background:
Intensive insulin regimens are now the mainstay of modern, type 1 diabetes mellitus management. Insulin pumps (CSII) are a key technique used. Although there has been considerable study of outcomes, there are few recent data on CSII-associated adverse events (AEs) and their incidence and characteristics.
Subjects And Methods:
Phone calls to our 24-h diabetes support service were screened for CSII-associated AEs. Phone interviews were conducted with the parent/patient, within 96 h of the event. Interviews explored AE characteristics and the role of the user, as well as questions relating to outcome and the impact to the family and patient. Comparisons were made with clinic CSII patients not reporting an AE.
Results:
Over a 16-week study period, 50 confirmed AEs occurred in 45 of 405 (11.1%) patients. This was annualized to an AE incidence of 40 AEs/100 person-years. Pump malfunction and infusion set/site failures were the most common events reported, occurring in 27 (54.0%) and 18 (36.0%) AEs, respectively. A user- or education-related issue was implicated in 22 (44.0%) events. Pump replacement occurred in 19 of 50 occurrences (38.0%). Additionally, 16 (32.0%) reported a hospital admission or emergency department attendance as a consequence. When compared with those on CSII not reporting an AE, AEs were associated with age <10 years (odds ratio=3.2 [95% confidence interval, 1.7-6.1]) but not with gender, glycosylated hemoglobin, diabetes duration, or pumping duration.
Conclusions:
This is the first prospective study to look at AEs in modern-generation insulin pumps. AEs appear common and should be anticipated. Their origin is multifactorial, with the pump, associated consumables, and the user all being important factors. Ongoing support and anticipatory education are essential to minimize pump-associated AEs and their impact.
Related Concept Videos
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Pharmacokinetics in Pediatric Patients: Overview and Drug Absorption
Pharmacokinetics in Pediatric Patients: Drug Metabolism
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Pharmacokinetics in Pediatric Patients: Drug Distribution