Related Experiment Video
Updated: Apr 30, 2026

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Differences of the anterior segment parameters in children with down syndrome
Lokman Aslan1, Murat Aslankurt, Adnan Aksoy
1Ophthalmology Department and.
Insights
Children with Down syndrome (DS) show significant differences in anterior segment parameters compared to healthy children. Corneal characteristics were most notably affected, highlighting the clinical significance for eye care in DS.
Area of Science:
- Ophthalmology
- Genetics
- Pediatrics
Background:
- Down syndrome (DS) is associated with various ocular abnormalities.
- Understanding anterior segment differences in children with DS is crucial for early detection and management.
Purpose of the Study:
- To investigate and compare anterior segment parameters between children with Down syndrome and healthy children.
- To determine the clinical significance of these differences.
Main Methods:
- A cross-sectional case-control study involving 38 children with DS and 42 healthy controls.
- Ophthalmologic examinations included slit-lamp biomicroscopy, cycloplegic refraction, and intraocular pressure measurement.
- Scheimpflug imaging (Pentacam) was utilized to analyze anterior segment structural indices.
Main Results:
- Children with DS exhibited significantly thinner corneas, smaller corneal volume, and reduced corneal curvature compared to controls (p < 0.001).
- Pupil size was also significantly smaller in children with DS (p < 0.05).
- Iridocorneal angle, anterior chamber volume, and anterior chamber depth showed no significant differences between the groups.
Conclusions:
- Most anterior segment parameters differ between children with Down syndrome and healthy children.
- Corneal parameters (thickness, volume, curvature) and pupil size are significantly altered in children with DS.
- These findings underscore the importance of comprehensive ophthalmic evaluations for children with Down syndrome, particularly focusing on corneal health.
Purpose:
The study was undertaken to investigate whether anterior segment findings are different in children with Down syndrome (DS) to normal children and to focus on its clinical significance.
Methods:
A cross-sectional case control study was conducted in a total of 38 children with DS and 42 healthy children. This is the first report in the literature stating that. All subjects underwent ophthalmologic examination including slit-lamp biomicroscopy, cycloplegic refraction, intraocular pressure measurement and Scheimpflug imaging measurement. Customized software for Pentacam was used to analyze structural indices of anterior segment parameters. The mean anterior segment values of right eyes were compared between the groups.
Results:
The mean anterior chamber parameters of patients with DS and controls were measured respectively: Corneal thickness was 502.31 ± 40.5 and 541.8 ± 37.42 mm (p < 0.001), corneal volume was 56.63 ± 4.5 and 61.02 ± 4.3 mm³ (p < 0.001), corneal radius curvature was 7.41 ± 0.29 and 7.67 ± 0.34 mm (p < 0.001), iridocorneal angle was 39.7 ± 6.2 and 39.5 ± 6.4° (p = 0.944), anterior chamber volume was 181.65 ± 27.38 and 185.77 ± 32.53 m³ (p = 0.528), anterior chamber depth was 3.08 ± 0.24 and 3.02 ± 0.31 mm (p = 447), pupil size was 2.95 ± 0.48 and 3.29 ± 0.45 mm (p < 0.05).
Conclusion:
The majority of the anterior segment parameters were found to be different in children with Down syndrome. While pupil size, corneal thickness, corneal volume and corneal curvature in DS were less than normal, iridocorneal angle, anterior chamber depth and anterior chamber volume were close to controls. The most important parametric differences in children with DS were seen on the cornea.
More Related Videos
03:35Determining Gender-Based Differences in Retinal and Choroidal Thickness in Underweight Individuals via Swept-Source Optical Coherence Tomography
Published on: December 1, 2023
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025