Related Experiment Video
Updated: Apr 30, 2026

Quantifying Intermembrane Distances with Serial Image Dilations
Published on: September 28, 2018
Assessing the imaging capabilities of radial mechanical and electronic echo-endoscopes using the resolution integral
Scott Inglis1, Anna Janeczko1, William Ellis1
1Medical Physics, NHS Lothian, Royal Infirmary of Edinburgh, Edinburgh, United Kingdom.
Abstract:
Over the past decade there have been significant advances in endoscopic ultrasound (EUS) technology. Although there is an expectation that new technology will deliver improved image quality, there are few methods or phantoms available for assessing the capabilities of mechanical and electronic EUS systems. The aim of this study was to investigate the possibility of assessing the imaging capability of available EUS technologies using measurements of the resolution integral made with an Edinburgh Pipe Phantom. Various radial EUS echo-endoscopes and probes were assessed using an Edinburgh Pipe Phantom. Measurements of the resolution integral (R), depth of field (LR) and characteristic resolution (DR) were made at all operating frequencies. The mean R value for Fuji miniprobes was 16.0. The GF-UM20 and GF-UM2000 mechanical radial scopes had mean R values of 24.0 and 28.5, respectively. The two electronic radial echo-endoscopes had similar mean R values of 34.3 and 34.6 for the Olympus GF-UE260 and Fujinon EG-530 UR scopes, respectively. Despite being older technology, the mechanical GF-UM2000 scope had superior characteristic resolution (DR), but could not compare with the depths of field (LR) delivered by the current generation of electronic radial scopes, especially at the standard operating frequencies of 7.5 and 12 MHz.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
04:35Author Spotlight: Advancing Biopsy Techniques with Transesophageal Ultrasound
Published on: November 21, 2023
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Endoscopic Procedures V: ERCP
Patient...