Evaluation and automatic correction of metal-implant-induced artifacts in MR-based attenuation correction in
G Schramm1, J Maus, F Hofheinz
1Helmholtz-Zentrum Dresden-Rossendorf, Institute of Radiopharmaceutical Cancer Research, Department of Positron-Emission-Tomography, Dresden, Germany. Technische Universität Dresden, Faculty of Medicine Carl Gustav Carus, Dresden, Germany.
Abstract:
The aim of this paper is to describe a new automatic method for compensation of metal-implant-induced segmentation errors in MR-based attenuation maps (MRMaps) and to evaluate the quantitative influence of those artifacts on the reconstructed PET activity concentration. The developed method uses a PET-based delineation of the patient contour to compensate metal-implant-caused signal voids in the MR scan that is segmented for PET attenuation correction. PET emission data of 13 patients with metal implants examined in a Philips Ingenuity PET/MR were reconstructed with the vendor-provided method for attenuation correction (MRMap(orig), PET(orig)) and additionally with a method for attenuation correction (MRMap(cor), PET(cor)) developed by our group. MRMaps produced by both methods were visually inspected for segmentation errors. The segmentation errors in MRMap(orig) were classified into four classes (L1 and L2 artifacts inside the lung and B1 and B2 artifacts inside the remaining body depending on the assigned attenuation coefficients). The average relative SUV differences (ε(rel)(av)) between PET(orig) and PET(cor) of all regions showing wrong attenuation coefficients in MRMap(orig) were calculated. Additionally, relative SUV(mean) differences (ε(rel)) of tracer accumulations in hot focal structures inside or in the vicinity of these regions were evaluated. MRMap(orig) showed erroneous attenuation coefficients inside the regions affected by metal artifacts and inside the patients' lung in all 13 cases. In MRMap(cor), all regions with metal artifacts, except for the sternum, were filled with the soft-tissue attenuation coefficient and the lung was correctly segmented in all patients. MRMap(cor) only showed small residual segmentation errors in eight patients. ε(rel)(av) (mean ± standard deviation) were: (-56 ± 3)% for B1, (-43 ± 4)% for B2, (21 ± 18)% for L1, (120 ± 47)% for L2 regions. ε(rel) (mean ± standard deviation) of hot focal structures were: (-52 ± 12)% in B1, (-45 ± 13)% in B2, (19 ± 19)% in L1, (51 ± 31)% in L2 regions. Consequently, metal-implant-induced artifacts severely disturb MR-based attenuation correction and SUV quantification in PET/MR. The developed algorithm is able to compensate for these artifacts and improves SUV quantification accuracy distinctly.
More Related Videos
10:02Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...