Liquid extraction surface analysis (LESA) of hydrophobic TLC plates coupled to chip-based nanoelectrospray
Markus Himmelsbach1, Emmanuel Varesio, Gérard Hopfgartner
1Life Sciences Mass Spectrometry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CH-1211 Geneva 4, Switzerland; Institute of Analytical Chemistry, Johannes Kepler University Linz, Altenberger Straße 69, A-4040 Linz, Austria.
Abstract:
Direct identification and structural characterization of analyte spots on TLC plates have always been of great interest and the development of interfaces that allow TLC to be combined with MS is making steady progress. The recently introduced liquid extraction surface analysis (LESA) approach has the potential to hyphenate TLC with MS. A mixture of lipid standards was separated on HPTLC RP-18 glass plates using chloroform:methanol :acetonitrile 2:1:1 (v:v:v) as mobile phase. After visualization with primuline dye (0.02% in acetone:water 8:2 (v:v)), LESA was performed, followed by a chip-based nanoflow infusion in combination with FTICRMS. The optimized extraction solvent composition was methanol:chloroform:water:formic acid 52:24:24:0.2 (v:v:v:v). A nanoelectrospray voltage of 1.6 kV and a gas pressure of 0.2 psi were applied in all experiments. All phospholipids were extracted successfully and detected unambiguously using the optimized TLC-LESA-FTICRMS procedure. Sampling the tricaprylin spot gave the most intense signals and also tricaprin was detected. Three other triacylglycerols of higher molecular mass have logP values between 15.5 and 21.6, which are the highest among all investigated compounds and are not detected from their corresponding spots, due to the fact that the solubility of very apolar lipids is not high enough in the extraction solvent. It was demonstrated that TLC can be elegantly combined with mass spectrometry based on the LESA approach. In general, apart from the analysis of lipids, TLC-LESA-MS has a high potential for medium-polar compounds separated on reversed-phase TLC plates, but limitations are present when very apolar compounds have to be extracted.
More Related Videos
08:37Sampling Human Indigenous Saliva Peptidome Using a Lollipop-Like Ultrafiltration Probe: Simplify and Enhance Peptide Detection for Clinical Mass Spectrometry
Published on: August 7, 2012
10:37Deep Proteome Profiling by Isobaric Labeling, Extensive Liquid Chromatography, Mass Spectrometry, and Software-assisted Quantification
Published on: November 15, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: