Related Experiment Video
Updated: Apr 30, 2026

Author Spotlight: A Reproductive Hysteroscopy Approach for Complete Endometrial Polyp Removal and Enhanced Endometrial Receptivity
Published on: August 2, 2024
Concomitant hysteroscopic endometrial ablation and Essure procedure: feasibility, efficacy and satisfaction
Y Levy-Zauberman1, G Legendre1, A Nazac1
1AP-HP, Hospital Bicêtre, Department of Gynaecology and Obstetric, 78 rue du Général Leclerc, 94270 Le Kremlin Bicêtre, France.
Objective:
Hysteroscopic endometrial destruction procedures for abnormal uterine bleeding are an alternative to hysterectomy. Such procedures are not contraceptive and are performed on fertile patients, requiring long-term contraception. This is the first study evaluating long-term results of a combined procedure associating endometrial destruction and concomitant hysteroscopic tubal sterilization by Essure(®) micro-inserts. Our goal is to evaluate efficacy of endometrial destruction as well as hysteroscopic sterilization and satisfaction after a combined procedure in the case of abnormal uterine bleeding in non-menopausal patients.
Study Design:
This is a retrospective study (Canadian task force II-2) that includes 131 patients operated with combined endometrial destruction and hysteroscopic tubal sterilization between 2002 and 2011 at our university hospital. The patients were contacted to answer a questionnaire. Statistical analysis was performed with SAS© version 9.2. (SAS Institute Inc., Cary, NC).
Results:
Ninety-three patients out of 131 could be reached. The mean follow-up was of 37.8 months (min=8, max=87, SD=6.2). Thirty-eight patients (29%) were lost to follow-up. Essure(®) micro-inserts introduction success rate (evaluated on 131 patients) was 95.8%, and their position was appropriate in 81.1% of the 106 patients with position control. Efficacy of the procedure on the haemorrhagic symptoms (evaluated on 93 patients) was 80.6%. Twelve patients (12.9%) underwent a hysterectomy, 7 of which (58.3%) were a direct consequence of treatment failure. No pregnancies were reported. Satisfaction rate was of 90.3%.
Conclusion:
Inadequate position rates of the micro-inserts after 3 months seem somewhat above literature findings, though no pregnancy has been reported. However, recurrent bleeding symptoms and hysterectomy rates are consistent with those observed after an endometrial destruction procedure alone. Limitations are the limited number of patients, the bias inherent to retrospective studies (lost of follow-up, selection bias). The concomitant endometrial destruction and tubal sterilization by micro-inserts is a safe and efficient procedure.
More Related Videos
07:07Endoscopy Guided Photoablation of Endometrial Cysts using a 980 nm Laser with a Contact Fiber in Mares
Published on: July 16, 2020
05:21Laparoscopic Extracorporeal Knot-Tying for Uterine Vessel Occlusion during Hysterectomy with Cervical Cerclage in Large Uteri
Published on: September 12, 2025