Related Experiment Video
Updated: Apr 30, 2026

Preoxygenation Techniques for Tracheal Intubation in Critically Ill Adults Utilizing Oxygen Mask and Noninvasive Ventilation
Published on: December 5, 2025
A randomised controlled trial of an automated oxygen delivery algorithm for preterm neonates receiving supplemental
James Zapata1, John Jairo Gómez, Robinson Araque Campo
1Grupo de Investigación, Centro Medico Imbanaco, Asociación Atem Health Care, Cali, Colombia.
Aim:
Providing consistent levels of oxygen saturation (SpO2 ) for infants in neonatal intensive care units is not easy. This study explored how effectively the Auto-Mixer(®) algorithm automatically adjusted fraction of inspired oxygen (FiO2 ) levels to maintain SpO2 within an intended range in extremely low birth weight infants receiving supplemental oxygen without mechanical ventilation.
Methods:
Twenty extremely low birth weight infants were randomly assigned to the Auto-Mixer(®) group or the manual intervention group and studied for 12 h. The SpO2 target was 85-93%, and the outcomes were the percentage of time SpO2 was within target, SpO2 variability, SpO2 >95%, oxygen received and manual interventions.
Results:
The percentage of time within intended SpO2 was 58 ± 4% in the Auto-Mixer(®) group and 33.7 ± 4.7% in the manual group, SpO2 >95% was 26.5% vs 54.8%, average SpO2 and FiO2 were 89.8% vs 92.2% and 37% vs 44.1%, and manual interventions were 0 vs 80 (p < 0.05). Brief periods of SpO2 < 85% occurred more frequently in the Auto-Mixer(®) group.
Conclusion:
The Auto-Mixer(®) effectively increased the percentage of time that SpO2 was within the intended target range and decreased the time with high SpO2 in spontaneously breathing extremely low birth weight infants receiving supplemental oxygen.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...