Related Experiment Video
Updated: Apr 30, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Longitudinal micromorphological 15-year results of posterior composite restorations using three-dimensional scanning
Wolfram Dietz1, Regina Montag2, Ulrike Kraft2
1Electron Microscopy Centre, Jena University Hospital, Germany.
Objectives:
Hybrid composite restorations in posterior teeth were evaluated over 15 years using the semiquantitative Clinical, Photographic and Micromorphologic (CPM) index. It was a further aim to quantitate the surface morphology by three-dimensional scanning electron microscopy (3D-SEM).
Methods:
Thirty seven hybrid composite restorations (Ketac-Bond/Visio-Molar X, ESPE, Seefeld/Germany) were longitudinally followed up. Parallel to clinical assessment replicas were taken at baseline, after 1, 5, 10 and 15 years and evaluated by SEM, and profilometrical analyses of 3D-SEM data were computed. The profilometrical results were statistically analysed by ANOVA. The level of significance was set to p<0.05.
Results:
The semiquantitative micromorphological evaluation exhibited the most considerable deterioration within the first year and up to 5 years of function. Less change was detected during the next 10 years. The profilometrical quantification showed raising depth of the negative marginal ledges with a mean of 27.2μm (range 0.6-94.5μm) after 10 years, with no statistically significant changes from 5 to 10 and 10 to 15 years. The 3D-SEM revealed marginal grooves beneath the level of the ledges (mean 34.5μm after 5 years) within the bonding zone, exposing enamel margins. Leakages, marginal fractures and surface roughness did not seriously deteriorate the quality of restorations.
Conclusions:
Hybrid composite restorations of Class I and II cavities surviving the first five years performed well over 15 years of function. Quantitative 3D-SEM profilometrical measurements revealed the dynamics of marginal behaviour over time.
Clinical Significance:
Long-term parallel clinical and micromorphological evaluation of posterior composite restorations of Class I and Class II cavities documented the clinical safety and acceptable longevity. The longitudinal 3D micromorphologic assessment of the surface changes and of the marginal behaviour revealed deteriorating as well as improving factors hidden in clinical performance.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:07Scanning Electron Microscopic Evaluation of Surface Defects of Remover Retreatment File After Single and Multiple Uses
Published on: October 11, 2024
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Three-Dimensional Microscopy in Microbiology
Scanning Electron Microscopy
Fundamental Principles
Accelerated...