Related Experiment Video
Updated: Apr 29, 2026

Free Radicals in Chemical Biology: from Chemical Behavior to Biomarker Development
Published on: April 15, 2013
Novel spectroscopic methods for determination of Cromolyn sodium and Oxymetazoline hydrochloride in binary mixture
Omar Abdel-Aziz1, A M El-Kosasy1, N Magdy1
1Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Organization of African Unity Street, Abassia, Cairo 11566, Egypt.
Abstract:
New accurate, sensitive and selective spectrophotometric and spectrofluorimetric methods were developed and subsequently validated for determination of Cromolyn sodium (CS) and Oxymetazoline HCl (OXY) in binary mixture. These methods include 'H-point standard addition method (HPSAM) and area under the curve (AUC)' spectrophotometric method and first derivative synchronous fluorescence spectroscopic (FDSFS) method. For spectrophotometric methods, absorbances were recorded at 241.5nm and 274.9nm for HPSAM and the wavelength was selected in ranges 232.0-254.0nm and 216.0-229.0nm for AUC method, where the concentration was obtained by applying Cramer's rule. For FDSFS method, the first-derivative synchronous fluorescence signal was measured at 290.0nm, using Δλ=145.0nm. The suggested methods were validated according to International Conference of Harmonization (ICH) guidelines and the results revealed that they were precise and reproducible. All the obtained results were statistically compared with those of the reported method and there was no significant difference.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Adrenergic Agonists: Mixed-Action Agents
Ephedrine and pseudoephedrine lack a catecholamine group, making them less susceptible to degradation by metabolic enzymes. They have increased oral bioavailability and lipophilicity, resulting in a longer duration of action. Their response is reduced by...
Racemic Mixtures and the Resolution of Enantiomers
Measuring Reaction Rates
Mass Spectrum: Interpretation