Bowel endometriosis: preoperative diagnostic accuracy of 3.0-T MR enterography--initial results
Pascal Rousset1, Noémie Peyron, Mathilde Charlot
1From Lyon 1 Claude Bernard University, Lyon, France (P.R., N.P., F.G., D.R., E.C., P.J.V.); and Departments of Radiology (P.R., N.P., M.C., F.C., F.R., P.J.V.), Obstetrics and Gynecology (F.G., D.R.), Oncologic and General Surgery (E.C.), and Pathology (S.I.), Hospices Civils de Lyon, Centre Hospitalier Lyon Sud, 165 Chemin du Grand Revoyet, 69495 Pierre Bénite, France.
Purpose:
To prospectively determine the accuracy of 3.0-T magnetic resonance (MR) enterography in the preoperative assessment of deep infiltrating endometriosis (DIE) lesions located in the bowel above the rectosigmoid junction.
Materials And Methods:
Institutional review board approval for this study was obtained, and each patient gave written informed consent. Over 18 months, patients with known pelvic DIE who were scheduled for surgery were recruited. Consecutive patients suspected of having bowel endometriosis above the rectosigmoid junction underwent 3.0-T MR enterography. Two blinded readers independently performed a systematic analysis of nine bowel segments above the rectosigmoid junction. MR images were compared with surgical and pathologic findings. Efficacy parameters were calculated with 95% confidence intervals (CIs). Interobserver agreement was assessed with κ statistics.
Results:
Among the 43 patients enrolled in this study, 33 underwent surgery and were included in the final analyses. Sixteen (48%) patients had bowel DIE lesions located above the rectosigmoid junction at surgery and histopathologic examination. Twenty-six lesions were analyzed, including four ileal, two ileocecal, three cecal, three appendicular, and 14 sigmoid colon lesions. For the diagnosis of these lesions, MR imaging showed sensitivities of 92% (95% confidence interval [CI]: 81.7, 100) for reader 1 and 96% (95% CI: 87.1, 100) for reader 2 and specificities of 100% (95% CI: 98.8, 100) for both readers. The κ value was 0.97.
Conclusion:
These results show 3.0-T MR enterography is accurate in the preoperative diagnosis and mapping of bowel DIE lesions located above the rectosigmoid junction. Online supplemental material is available for this article.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures V: ERCP
Patient...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...