A novel approach to fit testing the N95 respirator in real time in a clinical setting
Peggy Or1, Joanne Chung2, Thomas Wong3
1Department of Nursing and Health Sciences, Tung Wah College, Kowloon, Hong Kong.
Abstract:
The instant measurements provided by the Portacount fit-test instrument have been used as the gold standard in predicting the protection of an N95 respirator in a laboratory environment. The conventional Portacount fit-test method, however, cannot deliver real-time measurements of face-seal leakage when the N95 respirator is in use in clinical settings. This research was divided into two stages. Stage 1 involved developing and validating a new quantitative fit-test method called the Personal Respiratory Sampling Test (PRST). In Stage 2, PRST was evaluated in use during nursing activities in clinical settings. Eighty-four participants were divided randomly into four groups and were tested while performing bedside nursing procedures. In Stage 1, a new PRST method was successfully devised and validated. Results of Stage 2 showed that the new PRST method could detect different concentrations and different particle sizes inside the respirator while the wearer performed different nursing activities. This new fit-test method, PRST, can detect face seal leakage of an N95 respirator being worn while the wearer performs clinical activities. Thus, PRST can help ensure that the N95 respirator actually fulfils its function of protecting health-care workers from airborne pathogens.
Related Concept Videos
PPE Use in Healthcare Settings II: Doffing
PPE Use in Healthcare Settings I: Donning
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...