Related Experiment Video
Updated: Apr 29, 2026

A Modified Sonographic Algorithm for Image Acquisition in Life-Threatening Emergencies in the Critically Ill Newborn
Published on: April 7, 2023
Paramedics accurately apply the pediatric assessment triangle to drive management
Objective:
To provide an evaluation of the Pediatric Assessment Triangle (PAT) as an assessment tool for use by paramedic providers in the prehospital care of pediatric patients.
Methods:
Paramedics from Los Angeles Fire Department (LAFD) received training in the Pediatric Education for Prehospital Professionals (PEPP) course, PAT study procedures, and completed training in applying the PAT to assess children 0-14 years of age. A convenience sample of LAFD paramedic assessments of the pediatric patients transported to 29 participating institutions, over an 18-month period ending July 2010, were eligible for inclusion. Patients who were not transported were excluded from the study, as were the assessments of children with special health-care needs (CSHCN). PAT Study Forms, emergency medical services (EMS) report forms, and emergency department (ED) and hospital charts were entered into a secure database. Two study investigators, blinded to paramedic PAT assessment, reviewed hospital charts and determined the category of illness or injury.
Results:
A total of 1,552 PAT Study Forms were collected. Overall, 1,168 of the patient (75%) assessments met inclusion criteria, were transported, and had all three data points (PAT Study Form, paramedic EMS report form, and ED/hospital chart) available for analysis. When paramedics used the PAT to identify abnormalities in the three arms of the triangle (PAT Paramedic Pattern) and applied that pattern to form a general impression (PAT Paramedic Impression), the agreement resulted in a κ coefficient of 0.93 [95% CI: 0.91-0.95]. The PAT paramedic impression was congruent with field management, as the majority of patients received consistent interventions with local EMS protocols. The PAT Paramedic Impression for instability demonstrated a sensitivity of 77.4% [95% CI: 72.6-81.5%], a specificity of 90.0% [95% CI: 87.1-91.5%] with a positive likelihood ratio (LR+) of 7.7 [95% CI: 5.9-9.1] and a negative likelihood ratio (LR-) of 0.3 [95% CI: 0.2-0.3].
Conclusion:
The PAT is a rapid assessment tool that can be readily and reliably used by paramedics in the prehospital setting. The PAT should be used in conjunction with other assessments but can safely drive initial field management.
More Related Videos
08:22Measuring Cardiac Autonomic Nervous System ANS Activity in Toddlers - Resting and Developmental Challenges
Published on: February 25, 2016
08:22The Application of Point-of-Care Ultrasonography (POCUS) in the Management of Acute Respiratory Distress Syndrome (ARDS) in the Intensive Care Unit
Published on: December 12, 2025
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation I: Adult