A semi-automatic segmentation method for the structural analysis of carotid atherosclerotic plaques by computed
Florentino Luciano Caetano dos Santos1, Atte Joutsen, Mitsugu Terada
1Department of Electronics and Communications Engineering, Tampere University of Technology.
Aim:
Computed tomography angiography (CTA) is currently the most reliable imaging technique for evaluating and planning the treatment of atherosclerosis. The drawbacks of the technique are its low spatial resolution and challenging manual measurements. The purpose of this study was to develop a semi-automatic method to segment vessel walls, surrounding tissue, and the carotid artery lumen to measure the severity of stenosis.
Methods:
In vivo contrast CTA images from eight patients undergoing endarterectomy were analyzed using a tailored five-step process involving an adaptive segmentation algorithm and region growing to measure the maximum percent stenosis in the cross-sectional area of the carotid artery. The accuracy of this method was compared with that of manual measurements made by physicians.
Results:
There were no significant differences between the maximum percent stenosis value obtained using the semi-automatic tool and that obtained using manual measurements (6%; p=0.31). The data acquisition and analysis required an average of 145 seconds.
Conclusion:
This new semi-automatic segmentation method for CTA provides a fast and reliable tool to quantify the severity of carotid artery stenosis.
More Related Videos
13:45A Method to Study the Correlation Between Local Collagen Structure and Mechanical Properties of Atherosclerotic Plaque Fibrous Tissue
Published on: November 11, 2022
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT