Related Experiment Video
Updated: Apr 29, 2026

Experimental Methodology for Estimation of Local Heat Fluxes and Burning Rates in Steady Laminar Boundary Layer Diffusion Flames
Published on: June 1, 2016
Flame retardant exposures in California early childhood education environments
Asa Bradman1, Rosemary Castorina1, Fraser Gaspar1
1Center for Environmental Research and Children's Health (CERCH), School of Public Health, University of California, Berkeley, CA, USA.
Insights
Flame retardants like tris phosphate and PBDEs were found in California child care centers. Some children
Area of Science:
- Environmental Health
- Toxicology
- Pediatrics
Background:
- Millions of children attend early childhood education (ECE) facilities daily.
- Limited data exists on environmental exposures within these ECE settings.
- Flame retardants are common chemicals used in furnishings and electronics.
Purpose of the Study:
- To measure flame retardant levels in air and dust from California ECE facilities.
- To assess potential child exposure risks from these flame retardants.
Main Methods:
- Air and dust samples collected from 40 ECE facilities over one year.
- Analysis of six polybrominated diphenyl ether (PBDE) congeners and four non-PBDE flame retardants.
- Calculation of child dose estimates and comparison to reference doses (RfD) and California Proposition 65 guidelines.
Main Results:
- Flame retardants, including tris phosphate compounds (TCEP, TDCIPP) and PBDEs, were detected in all dust samples.
- Tris phosphate concentrations (TCEP, TDCIPP) were comparable to or higher than PBDEs.
- Higher TCEP and TDCIPP levels were found in facilities with foam napping equipment.
- Child exposure to BDE99 exceeded the reference dose in one facility.
- TDCIPP exposure exceeded California's "No Significant Risk Levels" for carcinogens in over half of the facilities for young children.
Conclusions:
- ECE facilities are significant indoor environments for young children's exposure to flame retardants.
- Flame retardants, particularly tris phosphates, are prevalent and may pose health risks to children.
- Further research is needed to identify effective strategies for reducing flame retardant sources in ECE environments.
Abstract:
Infants and young children spend as much as 50h per week in child care and preschool. Although approximately 13 million children, or 65% of all U.S. children, spend some time each day in early childhood education (ECE) facilities, little information is available about environmental exposures in these environments. We measured flame retardants in air and dust collected from 40 California ECE facilities between May 2010 and May 2011. Low levels of six polybrominated diphenyl ether (PBDE) congeners and four non-PBDE flame retardants were present in air, including two constituents of Firemaster 550 and two tris phosphate compounds [tris (2-chloroethyl) phosphate (TCEP) and tris (1,3-dichloroisopropyl) phosphate (TDCIPP)]. Tris phosphate, Firemaster 550 and PBDE compounds were detected in 100% of the dust samples. BDE47, BDE99, and BDE209 comprised the majority of the PBDE mass measured in dust. The median concentrations of TCEP (319 ng g(-1)) and TDCIPP (2265 ng g(-1)) were similar to or higher than any PBDE congener. Levels of TCEP and TDCIPP in dust were significantly higher in facilities with napping equipment made out of foam (Mann-Whitney p-values<0.05). Child BDE99 dose estimates exceeded the RfD in one facility for children<3 years old. In 51% of facilities, TDCIPP dose estimates for children<6 years old exceeded age-specific "No Significant Risk Levels (NSRLs)" based on California Proposition 65 guidelines for carcinogens. Given the overriding interest in providing safe and healthy environments for young children, additional research is needed to identify strategies to reduce indoor sources of flame retardant chemicals.
Related Concept Videos
Flame Photometry: Overview
Flame Photometry: Lab
Design Example: Flow Through a Fire Extinguisher
The key to understanding how the...
Atomic Emission Spectroscopy: Interference
Effects of Chemicals: Overview
Constant Volume Calorimetry