Flame retardant exposures in California early childhood education environments

Asa Bradman1, Rosemary Castorina1, Fraser Gaspar1

  • 1Center for Environmental Research and Children's Health (CERCH), School of Public Health, University of California, Berkeley, CA, USA.

Chemosphere
|May 20, 2014
PubMed

Insights

Flame retardants like tris phosphate and PBDEs were found in California child care centers. Some children

Area of Science:

  • Environmental Health
  • Toxicology
  • Pediatrics

Background:

  • Millions of children attend early childhood education (ECE) facilities daily.
  • Limited data exists on environmental exposures within these ECE settings.
  • Flame retardants are common chemicals used in furnishings and electronics.

Purpose of the Study:

  • To measure flame retardant levels in air and dust from California ECE facilities.
  • To assess potential child exposure risks from these flame retardants.

Main Methods:

  • Air and dust samples collected from 40 ECE facilities over one year.
  • Analysis of six polybrominated diphenyl ether (PBDE) congeners and four non-PBDE flame retardants.
  • Calculation of child dose estimates and comparison to reference doses (RfD) and California Proposition 65 guidelines.

Main Results:

  • Flame retardants, including tris phosphate compounds (TCEP, TDCIPP) and PBDEs, were detected in all dust samples.
  • Tris phosphate concentrations (TCEP, TDCIPP) were comparable to or higher than PBDEs.
  • Higher TCEP and TDCIPP levels were found in facilities with foam napping equipment.
  • Child exposure to BDE99 exceeded the reference dose in one facility.
  • TDCIPP exposure exceeded California's "No Significant Risk Levels" for carcinogens in over half of the facilities for young children.

Conclusions:

  • ECE facilities are significant indoor environments for young children's exposure to flame retardants.
  • Flame retardants, particularly tris phosphates, are prevalent and may pose health risks to children.
  • Further research is needed to identify effective strategies for reducing flame retardant sources in ECE environments.

Related Concept Videos

Flame Photometry: Overview01:02

Flame Photometry: Overview

Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
2.0K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
1.3K
Design Example: Flow Through a Fire Extinguisher01:12

Design Example: Flow Through a Fire Extinguisher

A fire extinguisher that uses pressurized water relies on fluid dynamics principles to generate a high-velocity stream capable of suppressing flames. The water is stored at a much higher pressure inside the extinguisher than the surrounding atmosphere. This pressure difference forces the water to flow rapidly when the extinguisher is activated, and the behavior of the water as it exits the nozzle can be understood using fundamental equations of fluid dynamics.
The key to understanding how the...
565
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
784
Effects of Chemicals: Overview01:27

Effects of Chemicals: Overview

Drugs, encompassing various chemical compounds from natural sources, lab synthesis, or genetic engineering, elicit different biological responses in living organisms. Some of these responses are desirable or therapeutic, while others are undesirable. The primary goal of administering a drug is to achieve a therapeutic effect, that is, to address a specific disease or health condition. Any concurrent effects outside of this therapeutic outcome are considered undesirable. These undesirable...
2.4K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
25.2K