Related Experiment Video
Updated: Apr 29, 2026

A High-throughput Method for Measurement of Glomerular Filtration Rate in Conscious Mice
Published on: May 10, 2013
Comparative study of three methods of estimation of creatinine clearance in critically ill patients
V Blasco1, F Antonini1, L Zieleskiewicz1
1Service d'anesthésie et de réanimation, hôpital Nord, Assistance publique-Hôpitaux de Marseille, Aix-Marseille université, chemin des Bourrely, 13015 Marseille, France.
Background:
At the bedside, the reference method for creatinine clearance determination is based on the measurement of creatinine concentrations in urine and serum (mCrCl). Several models are available to calculate the creatinine clearance from the serum creatinine concentration. This observational survey aimed at testing the hypothesis that the proposed equations are unreliable to determine accurate creatinine clearance in patients admitted to intensive care unit (ICU).
Method:
Creatinine clearance was determined by the use of mCrCl. Then, we compared three equations: Cockcroft-Gault (CG), Simplified Modification of Diet in Renal Disease (MDRDs), and Chronic Kidney Disease Epidemiology (CKD-EPI) in 156 consecutive patients within the first 24hours after ICU admission. We tested the hypothesis that the three equations were equivalent. The agreement between the three equations was evaluated by linear regression and Bland and Altman analysis.
Results:
Bland and Altman analysis showed similar agreement between the three equations. The biases and precisions were -4.8±51, -1.3±50, and 8.2±44 for CG, MDRDs, and CKD-EPI equations, respectively (P>0.05). The precisions were similar for the three equations (P>0.05). The percentages of outliers at ±30% were 44%, 45%, and 49% for CG, MDRDs, and CKD-EPI, respectively (P>0.05).
Conclusion:
Regarding the high percentage of outliers, the use of these equations cannot be recommended in ICU patients.
More Related Videos
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate