Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

2.2K
Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.2K
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

2.5K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.5K
Potentiometry: Overview01:06

Potentiometry: Overview

4.5K
Potentiometry is an analytical technique that measures the potential difference between two electrodes in an electrochemical cell without drawing any significant current that could alter the solution's composition. This method employs an indicator electrode, which exchanges electrons with the analyte solution, and a reference electrode with a constant potential. Each electrode is immersed in a solution comprised of two half-cells. In a conventional setup, the reference electrode serves as...
4.5K
The Electrical Double Layer01:30

The Electrical Double Layer

241
In the region where two bulk phases meet, an intricate electric charge distribution arises due to charge transfer, ion adsorption, molecular orientation, and charge distortion. This complex distribution is commonly referred to as the electrical double layer.When a solid electrode interfaces with ions in an electrolyte solution, the speed of electron transfer dictates the rates of oxidation and reduction. The electrode acquires a charge through the escape of atoms into the solution as cations or...
241

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Artificial Intelligence-Supported Colorimetric Multibiomarker Sensor to Enable Critical Neonatal Monitoring.

ACS sensors·2026
Same author

Green IoT Event Detection for Carbon-Emission Monitoring in Sensor Networks.

Sensors (Basel, Switzerland)·2024
Same author

Colorimetric Sensor Reading and Illumination Correction via Multi-Task Deep-Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2023
Same author

Advanced IoT Pressure Monitoring System for Real-Time Landfill Gas Management.

Sensors (Basel, Switzerland)·2023
Same author

Reshaping de Novo Protein Switches into Bioresponsive Materials for Biomarker, Toxin, and Viral Detection.

Advanced materials (Deerfield Beach, Fla.)·2022
Same author

Role of Working Temperature and Humidity in Acetone Detection by SnO<sub>2</sub> Covered ZnO Nanowire Network Based Sensors.

Nanomaterials (Basel, Switzerland)·2022

Related Experiment Video

Updated: Apr 29, 2026

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
09:36

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy

Published on: September 12, 2018

8.2K

A liquid-junction-free reference electrode based on a PEDOT solid-contact and ionogel capping membrane.

Claudio Zuliani1, Giusy Matzeu1, Dermot Diamond1

  • 1Clarity Centre for Sensor Web Technologies, National Centre for Sensor Research, Dublin City University, Dublin 9, Ireland.

Talanta
|May 21, 2014
PubMed
Summary

Researchers developed novel liquid-junction-free reference electrodes using poly-3,4-ethylenedioxythiophene (PEDOT) and ionogels. These solid-contact ionogel reference electrodes (SCI-REs) offer stable and cost-effective potentiometric sensing solutions.

Keywords:
Ion-Selective Electrode (ISEs)Ionic liquidIonogelPoly-3,4-ethylenedioxythiophene (PEDOT)Reference electrodeScreen printingSolid-contact

More Related Videos

Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
08:03

Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research

Published on: April 18, 2013

16.7K
Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
09:18

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique

Published on: May 3, 2015

13.6K

Related Experiment Videos

Last Updated: Apr 29, 2026

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
09:36

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy

Published on: September 12, 2018

8.2K
Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research
08:03

Multi-analyte Biochip MAB Based on All-solid-state Ion-selective Electrodes ASSISE for Physiological Research

Published on: April 18, 2013

16.7K
Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
09:18

Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique

Published on: May 3, 2015

13.6K

Area of Science:

  • Electrochemistry
  • Materials Science
  • Sensor Technology

Background:

  • Traditional reference electrodes often involve liquid junctions, which can lead to instability and contamination.
  • Developing stable, low-cost, and reliable reference electrodes is crucial for advancing potentiometric sensing applications.

Purpose of the Study:

  • To create liquid-junction-free reference electrodes on screen-printed substrates.
  • To investigate the impact of poly-3,4-ethylenedioxythiophene (PEDOT) properties on electrode stability.
  • To optimize ionogel capping membranes for high-performance reference electrodes.

Main Methods:

  • Screen printing of substrates.
  • Electropolymerization of poly-3,4-ethylenedioxythiophene (PEDOT) using potentiostatic and potentiodynamic techniques.
  • Formulation and optimization of ionogel capping membranes (acrylate monomers, ionic liquid, cross-linkers, photo-initiators).
  • Electrode characterization and calibration against commercial Ag/AgCl electrodes.

Main Results:

  • PEDOT film properties significantly influenced electrode stability during conditioning.
  • Optimized ionogel membranes yielded reference electrodes with performance comparable to commercial electrodes.
  • Calibration plots showed no significant difference between solid-contact ionogel reference electrodes (SCI-REs) and a double-liquid junction Ag/AgCl electrode for Na(+) ion-selective electrodes.

Conclusions:

  • Liquid-junction-free reference electrodes utilizing PEDOT solid contacts and ionogel membranes are feasible.
  • These SCI-REs demonstrate stability and performance on par with conventional electrodes.
  • This approach offers a promising pathway for developing low-cost potentiometric sensing components.