Head-of-bed elevation improves end-expiratory lung volumes in mechanically ventilated subjects: a prospective
Amy J Spooner1, Amanda Corley2, Nicola A Sharpe2
1Critical Care Research Group, Adult Intensive Care Services, The Prince Charles Hospital and University of Queensland, Chermside, Brisbane, Australia amy.spooner@health.qld.gov.au.
Background:
Head-of-bed elevation (HOBE) has been shown to assist in reducing respiratory complications associated with mechanical ventilation; however, there is minimal research describing changes in end-expiratory lung volume. This study aims to investigate changes in end-expiratory lung volume in a supine position and 2 levels of HOBE.
Methods:
Twenty postoperative cardiac surgery subjects were examined using electrical impedance tomography. End-expiratory lung impedance (EELI) was recorded as a surrogate measurement of end-expiratory lung volume in a supine position and at 20° and then 30°.
Results:
Significant increases in end-expiratory lung volume were seen at both 20° and 30° HOBE in all lung regions, except the anterior, with the largest changes from baseline (supine) seen at 30°. From baseline to 30° HOBE, global EELI increased by 1,327 impedance units (95% CI 1,080-1,573, P < .001). EELI increased by 1,007 units (95% CI 880-1,134, P < .001) in the left lung region and by 320 impedance units (95% CI 188-451, P < .001) in the right lung. Posterior increases of 1,544 impedance units (95% CI 1,405-1,682, P < .001) were also seen. EELI decreased anteriorly, with the largest decreases occurring at 30° (-335 impedance units, 95% CI -486 to -183, P < .001).
Conclusions:
HOBE significantly increases global and regional end-expiratory lung volume; therefore, unless contraindicated, all mechanically ventilated patients should be positioned with HOBE.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...