Related Experiment Video
Updated: Apr 29, 2026

Author Spotlight: Investigating HR-Dependent Cardiac Function in Mouse Models Through a Novel Atrial-Pacing Approach
Published on: July 21, 2023
Myocardial performance index in patients with dipper and nondipper hypertension
Cengiz Başar1, Feyzullah Beşli, Yasin Türker
1aDepartment of Cardiology, Düzce Atatürk State Hospital, Turkey Düzce State Hospital Departments of bCardiology cPathology, Düzce University Faculty of Medicine Hospital, Düzce dDepartment of Cardiology, Anatolia Hospital, Kastamonu eDepartment of Cardiology, Medeniyet University Faculty of Medicine Hospital, İstanbul, Turkey.
Insights
Left ventricular myocardial performance index (MPI) is elevated in hypertensive patients with the nondipper blood pressure pattern. This suggests MPI may help diagnose left ventricular dysfunction in nondipper hypertension.
Area of Science:
- Cardiology
- Hypertension Research
- Echocardiography
Background:
- Essential hypertension affects a significant portion of the population.
- The nondipper blood pressure pattern is associated with increased cardiovascular risk.
- Left ventricular myocardial performance index (LV MPI) is a marker of global left ventricular function.
Purpose of the Study:
- To investigate the relationship between LV MPI and the nondipper blood pressure pattern in hypertensive patients.
- To determine if LV MPI can serve as a diagnostic or monitoring tool for left ventricular dysfunction in nondipper hypertension.
Main Methods:
- Prospective study including hypertensive patients diagnosed with essential hypertension.
- Patients categorized into dipper and nondipper groups based on ambulatory blood pressure monitoring.
- Two-dimensional and Doppler echocardiography utilized to assess LV MPI from tissue Doppler imaging parameters.
Main Results:
- No significant differences in antihypertensive medication use, age, BMI, lipid profiles, or smoking status between dippers and nondippers.
- Significantly higher LV MPI values observed in the nondipper group compared to the dipper group.
- LV MPI showed a negative correlation with the rate of nocturnal systolic and diastolic blood pressure fall.
Conclusions:
- LV MPI is significantly disturbed in hypertensive patients exhibiting a nondipper pattern.
- LV MPI holds potential as a diagnostic and follow-up tool for global LV dysfunction in nondipper hypertension.
- Further prospective research is warranted to validate these findings.
Background:
The aim of this study was to evaluate the relationship between left ventricular (LV) myocardial performance index (MPI) and nondipper pattern in hypertensive patients.
Methods:
Between June 2012 and November 2012, patients admitted to the Cardiology Department of Düzce University Faculty of Medicine and diagnosed previously with essential hypertension were included in the study. Patients were divided into two groups, nondippers and dippers, using ambulatory blood pressure measurement. All patients were evaluated by two-dimensional and Doppler echocardiography. LV MPI was calculated from tissue Doppler imaging parameters.
Results:
There was no significant difference between the two groups in the proportion of each class of antihypertensive medications. Dippers and nondippers had similar age, BMI, lipid profiles, and smoking status. The MPI value was significantly higher in nondippers than in dippers, and was correlated negatively with the rate of systolic and diastolic blood pressure fall at night (P<0.001).
Conclusion:
Our study showed that MPI is disturbed in patients with nondipper hypertension. MPI may be used in the diagnosis and follow-up of global LV dysfunction in patients with a nondipper pattern, but further prospective studies are needed.
Related Concept Videos
Cardiomyopathy II: Dilated Cardiomyopathy
Cardiomyopathy III: Hypertrophic Cardiomyopathy
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiomyopathy V: Interprofessional Care

