Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences01:17

NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences

1.8K
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
1.8K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

7.6K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
7.6K
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

870
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
870
Atomic Nuclei: Magnetic Resonance01:05

Atomic Nuclei: Magnetic Resonance

1.2K
The number of nuclear spins aligned in the lower energy state is slightly greater than those in the higher energy state. In the presence of an external magnetic field, as the spins precess at the Larmor frequency, the excess population results in a net magnetization oriented along the z axis. When a pulse or a short burst of radio waves at the Larmor frequency is applied along the x axis, the coupling of frequencies causes resonance and flips the nuclear spins of the excess population from the...
1.2K
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

993
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
993

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Reductions in the white-gray functional connectome in preclinical Alzheimer's disease and their associations with amyloid and cognition.

Alzheimer's & dementia : the journal of the Alzheimer's Association·2024
Same author

White matter engagement in brain networks assessed by integration of functional and structural connectivity.

NeuroImage·2024
Same author

Layer-specific BOLD effects in gradient and spin-echo acquisitions in somatosensory cortex.

Magnetic resonance in medicine·2024
Same author

AI-assisted 3D analysis of grasping and reaching behavior of squirrel monkeys during recovery from cervical spinal cord injury.

Behavioural brain research·2024
Same author

Restriction-induced time-dependent transcytolemmal water exchange: Revisiting the Kӓrger exchange model.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2024
Same author

Functional correlation tensors in brain white matter and the effects of normal aging.

Brain imaging and behavior·2024
Same journal

Systematic comparison of MPRAGE and BRAVO T1-weighted MRI pulse sequences and brain morphometry in high-risk young adults.

Magnetic resonance imaging·2026
Same journal

Foot dynamic contrast-enhanced MRI for assessing microcirculatory changes after endovascular therapy in peripheral artery disease: A prospective pilot study.

Magnetic resonance imaging·2026
Same journal

Reconstruction of MRI from undersampled k-spaces of double-contrast volume acquisitions using deep neural networks.

Magnetic resonance imaging·2026
Same journal

Radiofrequency-induced heating safety of brain MRI scans at 7 T in the presence of a shoulder implant.

Magnetic resonance imaging·2026
Same journal

Incremental diagnostic value of microstructural time-dependent diffusion MRI in differentiating PCNSL from glioblastoma over conventional MRI.

Magnetic resonance imaging·2026
Same journal

Enhanced respiratory motion compensation in free-breathing dynamic contrast-enhanced MRI with GROG-facilitated bunch phase encoding and Golden angle radial sampling.

Magnetic resonance imaging·2026
See all related articles

Related Experiment Video

Updated: Apr 29, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K

Functional MRI using spin lock editing preparation pulses.

Swati Rane1, John T Spear2, Zhongliang Zu3

  • 1Vanderbilt University Institute of Imaging Science, Nashville, TN, USA; Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Nashville, TN, USA.

Magnetic Resonance Imaging
|May 23, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces a new method for brain imaging that uses specific radiofrequency pulses to better pinpoint the source of blood flow signals. By adjusting these pulses, researchers can filter out signals from large blood vessels and focus on the tiny vessels where brain activity actually happens, leading to more accurate mapping of brain function.

Keywords:
BOLDDiffusionIntravascularT1ρneuroimagingpulse sequencesvascular mappingmagnetic resonance

Frequently Asked Questions

More Related Videos

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

19.8K
Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.7K

Related Experiment Videos

Last Updated: Apr 29, 2026

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
09:30

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease

Published on: December 18, 2016

18.6K
The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism
13:56

The Use of Magnetic Resonance Spectroscopy as a Tool for the Measurement of Bi-hemispheric Transcranial Electric Stimulation Effects on Primary Motor Cortex Metabolism

Published on: November 19, 2014

19.8K
Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.7K

Area of Science:

  • Neuroimaging research within functional magnetic resonance imaging
  • Biomedical engineering and spin lock physics

Background:

No prior work had resolved how to isolate microvascular signals from larger venous contributions during standard brain scans. Conventional imaging methods often struggle to distinguish between these different vascular sources. That uncertainty drove the development of specialized pulse sequences. It was already known that magnetic field variations influence signal decay rates in the brain. Prior research has shown that these variations depend heavily on the size of the underlying blood vessels. This gap motivated the exploration of alternative relaxation parameters for functional imaging. Scientists have long sought ways to improve the spatial precision of brain activity maps. Researchers now investigate whether rotating frame relaxation can provide this needed selectivity.

Purpose Of The Study:

The researchers aimed to develop a novel imaging technique for detecting brain activity with higher spatial precision. They sought to address the limitations of conventional blood oxygenation level-dependent signals, which are often contaminated by large vessel effects. This study investigates whether rotating frame relaxation can selectively edit these unwanted signals. The team hypothesized that spin lock pulses could isolate microvascular contributions by manipulating extravascular diffusion. They intended to demonstrate that adjusting pulse amplitudes allows for the selective emphasis of different vascular scales. The project was motivated by the need for more accurate functional maps of the human brain. By exploring these specific magnetic resonance parameters, the authors hoped to refine the localization of neural responses. This work establishes a framework for using tunable contrast mechanisms in clinical and research imaging settings.

Main Methods:

The review approach involved evaluating a novel preparation sequence designed to modulate signal decay during magnetic resonance imaging. Investigators implemented a turbo spin echo protocol to test the efficacy of rotating frame relaxation. They applied two distinct locking field amplitudes to assess the sensitivity of the resulting contrast. The team performed these measurements on a group of eight healthy young adults. Data acquisition focused specifically on the visual cortex to observe neural activation patterns. The researchers compared these new findings against traditional T2 and T2-weighted imaging benchmarks. They utilized specific mathematical models to relate the observed relaxation rates to underlying vascular structures. This systematic evaluation allowed for the quantification of signal variations across different pulse settings.

Main Results:

Key findings from the literature demonstrate that spin lock pulses effectively modulate blood oxygenation level-dependent signals based on vascular size. The researchers observed a signal change of 1.1% when using an 80Hz locking field. Increasing the field to 400Hz resulted in a reduced signal change of 0.7%. In comparison, standard T2-weighted sequences produced a signal change of 1.3%. Conventional T2* imaging yielded the highest signal change at 1.9%. These results confirm that higher locking amplitudes suppress contributions from larger venous structures. The data indicate that rotating frame relaxation rates are sensitive to extravascular diffusion in magnetic field gradients. This evidence supports the use of tunable pulses to improve the spatial precision of brain activity measurements.

Conclusions:

The authors suggest that their rotating frame approach offers a unique way to tune sensitivity to specific vascular sizes. This technique allows for the suppression of large vessel interference in functional brain mapping. They propose that varying the locking field strength provides a window into the spatial distribution of magnetic field gradients. The findings indicate that this method successfully captures neural activation in the visual cortex. The researchers conclude that their approach enhances the spatial specificity of functional signals compared to standard methods. This work demonstrates that spin lock pulses can effectively edit extravascular diffusion effects. The study implies that future functional imaging could benefit from these tunable contrast mechanisms. These results provide a foundation for more precise localization of brain activity using magnetic resonance.

The researchers propose that spin lock pulses edit extravascular diffusion effects. By adjusting the amplitude of these pulses, they can selectively emphasize signals from microvasculature while reducing the influence of larger veins, which typically dominate conventional blood oxygenation level-dependent imaging.

The study utilizes a single-slice turbo spin echo sequence. This specific imaging tool incorporates spin lock preparation pulses at amplitudes of 80Hz and 400Hz to manipulate longitudinal relaxation rates in the rotating frame, allowing for the selective observation of different vascular scales.

A 3T magnetic field strength is necessary to achieve sufficient signal-to-noise ratios for detecting blood oxygenation level-dependent activation. The authors note that this field strength allows for the characterization of intrinsic magnetic field gradients across the human visual cortex.

The researchers use spin lock amplitude data to derive estimates of intrinsic gradient spatial scales. This measurement allows them to differentiate between signals originating from large-scale structures and those arising from smaller, more localized vascular networks.

The study measures blood oxygenation level-dependent signal changes in the visual cortex. They observed a 1.1% change at 80Hz and a 0.7% change at 400Hz, which they compared against standard T2-weighted and T2*-weighted sequences that yielded 1.3% and 1.9% changes, respectively.

The authors claim that this new contrast mechanism increases the spatial specificity of evoked responses. They suggest that by filtering out large vessel signals, the resulting functional maps more accurately reflect the actual location of neuronal activity.