Implementation and evaluation of a performance improvement intervention to address physician documentation
Vivek V Patil1, Bradley N Delman, Eric J Wilck
1Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY.
Purpose:
For ultrasound reports to meet criteria for coding as abdomen complete (USABC), 8 elements are required: liver, bile ducts, gallbladder, spleen, kidneys, pancreas, inferior vena cava (IVC), and aorta. Failure to document all 8 results in coding as ultrasound abdomen limited. The purposes of our study were to identify deficiencies in documentation, implement a performance improvement intervention to address deficiencies, and evaluate the intervention.
Methods:
In the first phase, 50 consecutive USABC reports performed as part of routine medical care were retrospectively analyzed for the presence or absence of the 8 elements required for USABC coding. Subsequently, education regarding current procedural terminology coding in abdominal ultrasound and standardized macros was provided to radiologists. In the second, postintervention phase, an additional 50 consecutive USABC reports were analyzed for the presence or absence of the 8 elements.
Results:
In the first phase, none (0%) of 50 reports met criteria for USABC. The most commonly omitted elements were IVC (present in 2% of reports) and aorta (present in 6%). After intervention, there was an increase to 37 reports (74%) meeting criteria for USABC. The most commonly omitted elements were IVC (present in 76%) and aorta (present in 86%). Lack of 100% compliance was secondary to failure to update a macro and inaccurately scheduled studies (focused right lower quadrant/appendicitis study scheduled as USABC).
Conclusions:
We improved USABC documentation from 0% to 74%. Our compliance rate after intervention was similar to the 75.1% of previously published larger studies. Our study illustrates the efficacy of simple performance improvement interventions to improve abdominal ultrasound documentation.
More Related Videos
Related Concept Videos
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Imaging Studies II: Ultrasonography
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Assessment of the Abdomen II: Percussion
Percussion
Percussion is an essential...