Related Experiment Video
Updated: Apr 29, 2026

The Left Pneumonectomy Combined with Monocrotaline or Sugen as a Model of Pulmonary Hypertension in Rats
Published on: March 8, 2019
Exaggerated blood pressure variability in patients with pneumoconiosis: a pilot study
Yuki Imaizumi1, Kazuo Eguchi2, Akira Taketomi3
1Munakata Oshima Clinic, Fukuoka, Japan; Division of Cardiovascular Medicine, Department of Medicine, Jichi Medical University, Tochigi, Japan;
Background:
Chronic hypoxia is a risk factor for cardiovascular disease, but its association with blood pressure (BP) remains unclear. We performed this study to clarify the hypothesis that chronic hypoxia is associated with abnormal BP variability in patients with pneumoconiosis.
Methods:
We recruited 19 patients with pneumoconiosis and 30 age- and BP level-matched control subjects. We used simultaneous pulse oximetry and ambulatory BP monitoring for all subjects. We evaluated their BP levels and variability by determining the SD and coefficient of variation (CV) of the BP data. The dipper pattern was defined as nocturnal BP fall ≥10%; the nondipper pattern was defined as nocturnal BP fall ≥0% but <10%; the riser pattern was defined as nocturnal BP fall <0%. Pearson and Spearman correlation coefficients were used to calculate the correlations between parameters.
Results:
In patients with pneumoconiosis, the daytime systolic BP (SBP) level was lower, the CV in 24-hour SBP (P < 0.05) and diastolic BP (P < 0.001) were higher than that in control subjects. And although not statistically significant (P = 0.13), the odds ratio of riser pattern was 3.73 in patients with pneumoconiosis, and their nighttime pulse rate was significantly higher (P < 0.05) than that in control subjects. The median daytime pulse oximetry oxygen saturation was inversely associated with mean (r = -0.30; P < 0.01) and SD (r = -0.38; P < 0.001) in daytime SBP. The median nighttime pulse oximetry oxygen saturation was inversely associated (r = -0.55; P < 0.001) and the mean nighttime pulse rate was associated (r = 0.51; P < 0.001) with CV in nighttime SBP. Partial pressure of oxygen was inversely associated with CV in daytime SBP (r = -0.24; P < 0.05).
Conclusions:
Exaggerated BP variability was seen in patients with pneumoconiosis, and the measures of hypoxia were associated with large fluctuations in ambulatory BP. Chronic and intermittent hypoxia could be the contributing factors of these findings.
Clinical Trial Registration:
Clinical Trial Number UMIN000000894 (University Hospital Medical Information Network Clinical Trials Registry website).
More Related Videos
04:54Invasive Hemodynamic Assessment for the Right Ventricular System and Hypoxia-Induced Pulmonary Arterial Hypertension in Mice
Published on: October 24, 2019
08:12Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Related Concept Videos
Measurement of Blood Pressure
Pneumothorax II: Pathophysiology
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Errors occurring during blood pressure monitoring
Several factors...
Blood Pressure