Dual-source CT versus single-source 64-section CT angiography for coronary artery disease: A meta-analysis
Related Experiment Video
Updated: Apr 29, 2026

Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
1Department of Radiology, BenQ Medical Center, Nanjing Medical University, 71 Hexi Street, Jianye District, Nanjing 210019, China.
Insights
Dual-source CT and single-source 64-section CT show similar ability to rule out coronary artery disease (CAD). However, dual-source CT offers higher specificity, leading to more accurate decisions for subsequent procedures.
Area of Science:
- Cardiology
- Radiology
- Medical Imaging
Background:
- Coronary artery disease (CAD) is a leading cause of mortality worldwide.
- Accurate non-invasive diagnostic tools are crucial for timely intervention.
- Computed tomography (CT) angiography has emerged as a key imaging modality for CAD assessment.
Purpose of the Study:
- To compare the diagnostic performance of single-source 64-section CT versus dual-source CT angiography in diagnosing CAD.
- To evaluate the accuracy of these CT modalities using invasive coronary angiography as the reference standard.
Main Methods:
- A meta-analysis was conducted, pooling data from 51 original papers.
- Inclusion criteria focused on studies defining significant CAD as ≥50% luminal diameter reduction.
- Data from 3966 patients (single-source CT) and 2047 patients (dual-source CT) were analyzed using a random-effects model.
Main Results:
- Both CT modalities demonstrated high sensitivity (97%) for CAD detection.
- Dual-source CT showed significantly higher specificity (86% vs. 78%) and negative predictive value (97% vs. 93%) compared to single-source CT.
- Positive predictive value and positive likelihood ratio were also significantly higher for dual-source CT.
Conclusions:
- Dual-source CT and single-source 64-section CT have comparable utility in ruling out CAD in intermediate-risk patients due to similar negative likelihood ratios.
- Dual-source CT offers superior specificity, enhancing the accuracy of CT-based decisions for coronary catheter angiography.
Aim:
To perform a meta-analysis to compare the diagnostic performance of single-source 64-section computed tomography (CT) versus dual-source CT angiography for diagnosis of coronary artery disease (CAD).
Materials And Methods:
The Cochrane Library, MEDLINE, and EMBASE were searched for relevant original papers. Inclusion criteria were (1) significant CAD defined as ≥50% reduction in luminal diameter by invasive coronary angiography as reference standard; (2) single-source 64-section CT or dual-source CT was used; (3) results were reported in absolute numbers of true-positive, false-positive, true-negative, and false-negative results or sufficiently detailed data for deriving these numbers were presented. A random-effects model was used for the meta-analysis.
Results:
Fifty-one papers including 3966 patients who underwent single-source 64-section CT and 2047 patients who underwent dual-source CT at a per-patient level were pooled. The diagnostic values of single-source 64-section CT versus dual-source CT were 97% versus 97% for sensitivity (p = 0.386), 78% versus 86% for specificity (p < 0.001), 90% versus 85% for positive predictive value (PPV; p < 0.001), 93% versus 97% for negative predictive value (NPV; p = 0.001), 6.8 versus 6.5 for positive likelihood ratio (p = 0.018), 0.04 versus 0.04 for negative likelihood ratio (p = 0.625), and 191.59 versus 207.37 for diagnostic odds ratio (p = 0.043), respectively.
Conclusion:
Dual-source CT and single-source 64-section CT have similar negative likelihood ratios and, therefore, there was no significant difference in their utility to rule out CAD in intermediate-risk patients. However, compared to single-source 64-section CT, dual-source CT has significantly higher specificity, so that CT-based decisions for subsequent coronary catheter angiography are more accurate.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Acute Coronary Syndrome III: Diagnostic Studies
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System IV: CMRI