Summary
Fiber-reinforced composite resin (FRCR) space maintainers offer a viable alternative to traditional methods in pediatric dentistry. However, their long-term success is limited, suggesting suitability only for short-term applications.
Area of Science:
- Pediatric Dentistry
- Dental Materials Science
Background:
- Conventional space maintainers require lengthy laboratory fabrication.
- Fiber-reinforced composite resin (FRCR) offers promising material properties for dental applications.
Purpose of the Study:
- To clinically assess the long-term efficacy of FRCR space maintainers using Ribbond®.
- Evaluate the performance of FRCR space maintainers over an 18-month period in children.
Main Methods:
- Thirty FRCR space maintainers were placed in children aged 6-9 years.
- Clinical follow-up evaluations were conducted at 1, 6, 12, and 18 months.
- Survival rates and statistical analysis were performed.
Main Results:
- Maxillary appliances demonstrated higher survival rates than mandibular appliances.
- The mean survival time for FRCR space maintainers was 12 months (range: 1-18 months).
Conclusions:
- FRCR space maintainers (Ribbond®) show potential as a short-term alternative to conventional band-loop space maintainers.
- Further research may be needed to improve the long-term durability of FRCR space maintainers.