Related Experiment Video
Updated: Apr 29, 2026

Laparoscopic Repair of Para-Esophageal Hernia Using Absorbable Biosynthetic Mesh
Published on: September 11, 2021
Staple line as a cause of unusual early internal hernia after appendectomy
Meenakshi Rajan1, Fernando Dip1, Samuel Szomstein1
1Section of Minimally Invasive and Endoscopic Surgery, Cleveland Clinic Florida, Weston, FL, USA.
Abstract:
The use of mechanical stapling devices in laparoscopic appendectomies has become a common practice. Occasionally, the retained staples have been described to cause adhesions that might result in bowel obstruction. Early bowel obstruction after routine abdominal surgery should be closely investigated and might warrant early re-exploration. We present a rare case of small bowel obstruction caused by a staple line adhesive band one week after appendectomy. A 46-year-old female underwent laparoscopic appendectomy for uncomplicated appendicitis. A linear endoscopic stapling device was utilized during the procedure. The patient was discharged without complication. One week later, the patient presented to the emergency room for abdominal pain and she was discharged after adequate pain control. Several hours later she returned with similar symptoms, and she was diagnosed with distal small bowel obstruction by computed tomography scan. During the diagnostic laparoscopy there was an internal hernia through a defect created by the appendiceal staple line and the adjacent small bowel mesentery. After reduction of the hernia, the small bowel venous drainage improved, and no intestinal resection was necessary. The offending staple was removed and the staple line covered with omentum. The patient had complete resolution of symptoms and she was discharged the following day. No perioperative complications occurred. Mechanical staplers are routinely used in laparoscopic appendectomy. The staple line should be inspected at the end of the procedure to confirm the absence of free, unformed staples that can generate adhesions and postoperative complications.
Insights
A rare case of small bowel obstruction caused by a staple line adhesive band after laparoscopic appendectomy highlights the importance of inspecting staple lines to prevent adhesions and potential bowel obstruction.
Area of Science:
- Gastroenterology
- Minimally Invasive Surgery
Background:
- Mechanical stapling devices are frequently used in laparoscopic appendectomies.
- Retained staples can occasionally lead to adhesions, potentially causing bowel obstruction.
Observation:
- A patient developed distal small bowel obstruction one week after laparoscopic appendectomy.
- Computed tomography revealed an internal hernia through a defect related to the appendiceal staple line.
Findings:
- Laparoscopic re-exploration identified an internal hernia caused by the appendiceal staple line.
- Removal of the offending staple and omental coverage resolved the obstruction without requiring intestinal resection.
Implications:
- This case underscores the importance of meticulous inspection of staple lines post-laparoscopic appendectomy.
- Preventing free staples can mitigate the risk of adhesion formation and subsequent bowel obstruction.
Related Concept Videos
Appendicitis-I: Introduction
Etiology: Appendicitis can arise from various causes, primarily rooted in the obstruction of the appendix lumen. Factors contributing to this obstruction include fecal accumulation, lymphoid hyperplasia and, in...
Appendicitis
Appendicitis-II: Diagnostic Studies and Management
Diagnosing Appendicitis
It requires a multifaceted approach, starting with a detailed physical examination to pinpoint the location and nature of the pain and identify any associated symptoms. Laboratory tests play a crucial role. A complete Blood Count (CBC) typically reveals leukocytosis (an increased number of...
Hiatal Hernia
Diverticular Disease of the Colon
Intestinal Obstruction I: Introduction