Spatial differences and temporal changes in illicit drug use in Europe quantified by wastewater analysis
Christoph Ort1, Alexander L N van Nuijs, Jean-Daniel Berset
1Swiss Federal Institute of Aquatic Science and Technology (Eawag), Dübendorf, Switzerland.
Aims:
To perform wastewater analyses to assess spatial differences and temporal changes of illicit drug use in a large European population.
Design:
Analyses of raw wastewater over a 1-week period in 2012 and 2013.
Setting And Participants:
Catchment areas of wastewater treatment plants (WWTPs) across Europe, as follows: 2012: 25 WWTPs in 11 countries (23 cities, total population 11.50 million); 2013: 47 WWTPs in 21 countries (42 cities, total population 24.74 million).
Measurements:
Excretion products of five illicit drugs (cocaine, amphetamine, ecstasy, methamphetamine, cannabis) were quantified in wastewater samples using methods based on liquid chromatography coupled to mass spectrometry.
Findings:
Spatial differences were assessed and confirmed to vary greatly across European metropolitan areas. In general, results were in agreement with traditional surveillance data, where available. While temporal changes were substantial in individual cities and years (P ranging from insignificant to <10(-3) ), overall means were relatively stable. The overall mean of methamphetamine was an exception (apparent decline in 2012), as it was influenced mainly by four cities.
Conclusions:
Wastewater analysis performed across Europe provides complementary evidence on illicit drug consumption and generally concurs with traditional surveillance data. Wastewater analysis can measure total illicit drug use more quickly and regularly than is the current norm for national surveys, and creates estimates where such data does not exist.
More Related Videos
06:06Color Spot Test As a Presumptive Tool for the Rapid Detection of Synthetic Cathinones
Published on: February 5, 2018
05:46Identification of Pharmaceuticals in The Aquatic Environment Using HPLC-ESI-Q-TOF-MS and Elimination of Erythromycin Through Photo-Induced Degradation
Published on: August 1, 2018
Related Concept Videos
Drug Concentrations: Measurements
Plasma...
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
Therapeutic Drug Monitoring: Drug Analysis Methods