Related Experiment Video
Updated: Apr 29, 2026

Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Published on: May 7, 2019
Missed cervical disc bulges diagnosed with kinematic magnetic resonance imaging
Lifeng Lao1, Michael D Daubs, Trevor P Scott
1Department of Orthopaedic Surgery, Renji Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China.
Purpose:
To determine if adding flexion and extension MRI studies to the traditional neutral views would be beneficial in the diagnosis of cervical disc bulges.
Methods:
Five hundred patients underwent MRI in neutral, flexion and extension positions. The images were analyzed using computer software to objectively quantify the amount of disc bulge.
Results:
Compared to the neutral position, cervical disc bulges were significantly increased in the extension position (P < 0.05), but on flexion position, there was no significant difference (P > 0.05). For patients without or <3 mm of disc bulge in neutral, 2.97% demonstrated an increase in bulge to ≥3 mm bulge in flexion, and 16.41% demonstrated an increase to ≥3 mm bulge in extension. For patients in the neutral view that had a baseline disc bulge of 3-5 mm, 3.73% had increased bulges to ≥5 mm in flexion and 11.57% had increased bulges to ≥5 mm in extension.
Conclusion:
A significant increase in the degree of cervical disc bulge was found by examining extension views when compared with neutral views alone. Kinematic MRI views provide valuable added information, especially in situations where symptomatic radiculopathy is present without any abnormalities demonstrated on traditional neutral MRI.
Related Concept Videos
Magnetic Resonance Imaging
Herniated Intervertebral Disc l: Introduction
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...