Related Experiment Video
Updated: Apr 28, 2026

Non-invasive Imaging of Acute Allograft Rejection after Rat Renal Transplantation Using 18F-FDG PET
Published on: April 28, 2013
FDG PET for diagnosing infection in hip and knee prostheses: prospective study in 221 prostheses and subgroup
Sandip Basu1, Thomas C Kwee, Babak Saboury
1From the *Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, PA; †Radiation Medicine Centre (BARC), Tata Memorial Centre Annexe, Parel, Bombay, Maharashtra, India; ‡Department of Radiology, University Medical Center Utrecht, Utrecht, Utrecht, the Netherlands; §Department of Orthopedic Surgery, Penn Presbyterian Medical Center, Philadelphia, PA; ¶Department of Radiology, Children's Hospital of Philadelphia, Philadelphia, PA; and ∥Department of Nuclear Medicine, All India Institute of Medical Sciences, New Delhi, Delhi, India.
Purpose:
This study aims to assess and compare the value of FDG PET with combined In-labeled leukocyte/Tc-sulfur colloid bone marrow (WBC/BM) imaging for diagnosing infection in hip and knee prostheses.
Methods:
In this prospective study, patients with painful hip or knee arthroplasty, who were scheduled to undergo clinical and diagnostic evaluation for prosthesis revision, were included. They have been studied by using FDG PET and WBC/BM scan. This study was institutional review board approved and Health Insurance Portability and Accountability Act compliant. All patients provided written informed consent.
Results:
A total of 134 hip and 87 knee prostheses, suspected of being either infected or noninfectious loosening, were evaluated. All 221 prostheses underwent FDG PET, whereas both WBC/BM imaging and FDG PET were performed in 88 prostheses. The initial analysis of data from the WBC/BM images demonstrated somewhat suboptimal results compared with those of FDG PET scans on 88 patients. In addition, some patients were not willing to undergo both procedures and therefore participate in this study. Therefore, a decision was made to eliminate WBC/BM imaging from the procedures for the remainder of this research study. This decision was reached partly because of the significant radiation dose delivered from labeled WBC and safety issues related to preparing these labeled cells. Final diagnosis was based on microbiological examinations of the surgical specimens in 125 prostheses and joint aspirations combined with the clinical follow-up of 6 months or more in 86 prostheses. The sensitivity, specificity, positive predictive value, and negative predictive value of FDG PET in hip prostheses were 81.8%, 93.1%, 79.4%, and 94.0%, respectively, and in knee prostheses were 94.7%, 88.2%, 69.2%, and 98.4%, respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of WBC/BM imaging in hip prostheses were 38.5%, 95.7%, 71.4%, and 84.6%, respectively, and in knee prostheses were 33.3%, 88.5%, 25.0%, and 92.0%, respectively. In those cases that underwent both FDG PET and WBC/BM imaging, there was a trend (P = 0.0625) toward a higher sensitivity for FDG PET in hip prostheses, whereas other comparisons did not show any significant differences between the 2 imaging modalities.
Conclusions:
Based on this study, the diagnostic performance of FDG PET scan in detecting infection in painful hip and knee prostheses is optimal for routine clinical application. Considering the complexity and costs of WBC/BM imaging and related safety issues associated with this preparation, FDG PET seems to be an appropriate alternative for assessing these patients.
More Related Videos
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET