Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

891
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
891
Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Positron Emission Tomography01:29

Positron Emission Tomography

6.2K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
6.2K
Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

850
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
850
Imaging Studies for Cardiovascular System V: CT01:28

Imaging Studies for Cardiovascular System V: CT

658
Cardiac computed tomography (CT) scanning is an advanced cardiac imaging technique that utilizes CT technology, with or without intravenous (IV) contrast, to produce accurate cross-sectional virtual slices of specific areas of the heart, coronary circulation, and major blood vessels such as the aorta, pulmonary veins, and arteries. The computer processes these slices to generate three-dimensional images. Multidetector CT (MDCT) is a rapid form of CT scanning that captures multiple slices...
658

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Clinical benefits and current challenges of photon-counting detector CT in vascular imaging.

Radiology advances·2026
Same author

Hallucination at low radiation dose: Evaluation of two deep-learning reconstruction methods in high-resolution chest CT.

Proceedings of SPIE--the International Society for Optical Engineering·2026
Same author

Accuracy and precision of automated kidney stone detection on CT.

Abdominal radiology (New York)·2026
Same author

The Uncoupling of CT Dose and Noise.

Radiology·2026
Same author

A framework for quantifying and leveraging uncertainty in pre-trained CT denoising model.

IEEE transactions on bio-medical engineering·2026
Same author

Mitigating CT number variability between scanners, tube potentials, and patient sizes using spectral CT virtual monoenergetic imaging.

Physics in medicine and biology·2026
Same journal

Effective contrast-enhanced preprocessing for intracranial artery segmentation in digital subtraction angiography.

Physics in medicine and biology·2026
Same journal

Improving Plan Quality in Adaptive Proton Therapy Using an Interactive Dose Modification Tool.

Physics in medicine and biology·2026
Same journal

Technical Note: Real-Time MLC Control and Latency Measurement Optimization with External Verification.

Physics in medicine and biology·2026
Same journal

Fetus-Specific Hematopoietic Stem Cell Dosimetry Framework for Leukemia-Relevant Target Cells During Prenatal Development.

Physics in medicine and biology·2026
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Apr 28, 2026

Perceptual and Category Processing of the Uncanny Valley Hypothesis' Dimension of Human Likeness: Some Methodological Issues
07:34

Perceptual and Category Processing of the Uncanny Valley Hypothesis' Dimension of Human Likeness: Some Methodological Issues

Published on: June 3, 2013

19.5K

Correlation between human and model observer performance for discrimination task in CT.

Yi Zhang1, Shuai Leng, Lifeng Yu

  • 1Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.

Physics in Medicine and Biology
|May 31, 2014
PubMed
Summary
This summary is machine-generated.

A modified channelized Hotelling model observer (CHO) accurately predicts human performance in computed tomography (CT) image quality tasks. Iterative reconstruction (IR) generally improved detection over filtered backprojection (FBP).

More Related Videos

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.7K
Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging
10:10

Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging

Published on: January 30, 2026

657

Related Experiment Videos

Last Updated: Apr 28, 2026

Perceptual and Category Processing of the Uncanny Valley Hypothesis' Dimension of Human Likeness: Some Methodological Issues
07:34

Perceptual and Category Processing of the Uncanny Valley Hypothesis' Dimension of Human Likeness: Some Methodological Issues

Published on: June 3, 2013

19.5K
Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
05:49

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization

Published on: February 23, 2024

1.7K
Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging
10:10

Evaluating Tests of Cognition using a Computerized Touch-Sensitive Tablet, Eye Tracking, and Functional Magnetic Resonance Imaging

Published on: January 30, 2026

657

Area of Science:

  • Medical Imaging Physics
  • Radiology
  • Image Quality Assessment

Background:

  • Objective physical metrics for computed tomography (CT) image quality lack clinical relevance.
  • Predicting human observer performance offers a more accurate assessment of clinical image quality.
  • Model observers, like the channelized Hotelling model observer (CHO), are being developed to simulate human visual perception.

Purpose of the Study:

  • To compare the performance of a modified channelized Hotelling model observer (CHO) with human observers in a CT shape discrimination task.
  • To evaluate the ability of the modified CHO to predict human observer performance across various imaging conditions.
  • To assess the impact of iterative reconstruction (IR) versus filtered backprojection (FBP) on observer performance.

Main Methods:

  • Lesion-mimicking rods (varying contrast, size, shape) were inserted into a torso phantom and scanned using a 128-slice CT scanner at five dose levels.
  • CT images were reconstructed using both filtered backprojection (FBP) and iterative reconstruction (IR) algorithms.
  • A modified CHO with an edge mask was developed to mimic human emphasis on lesion boundaries; its performance was compared to three human observers in a two-alternative forced choice task.

Main Results:

  • For small lesions, the modified CHO's performance strongly correlated with human observers across different contrasts, doses, and reconstruction methods.
  • A ceiling effect in performance was observed for both human and model observers with large lesions at high doses.
  • Iterative reconstruction (IR) significantly improved observer performance (both human and model) compared to filtered backprojection (FBP), particularly for smaller lesions and lower doses.

Conclusions:

  • The modified channelized Hotelling model observer (CHO) shows significant potential for predicting human observer performance in CT image quality assessment for both FBP and IR.
  • Iterative reconstruction (IR) offers a notable advantage over FBP for lesion detection tasks, with performance gains dependent on lesion characteristics and radiation dose.
  • The study highlights the clinical relevance of model observers in evaluating CT image quality and optimizing reconstruction techniques.